Türkiye'de yüksek sismik bölgelerde bulunan kendinden ankrajlı tankların sismik performansı
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
This study examines the seismic performance of three unanchored industrial liquid storage tanks that are located in the Kocaeli industrial area, which has a significant earthquake risk. One of the tanks is an existing tank in an industrial facility located in the region, while the other two were designed to have different anchorage ratios. The finite element analysis software ABAQUS was used to build 3-D finite element models in order to assess the seismic performance of the tanks. The seismic behaviour of the tanks was studied by performing time-history analyses using the recorded earthquake records that were scaled for the tank location. The spring-mass model, on which the developed tank models are based, models liquid content as two-point masses that were spring-adjusted to the tank wall. This approach was based on American Petroleum Institute (API 650). Tank-liquid interaction, base uplift, tank sliding off its foundation, damage to the tank's wall shell plates as well as bottom base plates, and the tank earthquake performance were all analysed. In addition, the effects of different friction coefficients between tank base and its foundation on tank seismic performance were studied. The seismic analyses were carried out using data related to eleven earthquakes. This data was scaled to meet the seismic design spectrum for the tank location and chosen in compliance with the Turkish Building Earthquake Code. Tank base sliding, base uplift and material damage were monitored to assess potential tank damages. The main objective of the study was to investigate the effects of tank anchorage ratio on seismic performance of unanchored tanks located in high seismic regions. This was achieved by performing time history analysis of the tanks using 11 earthquake records. Also, tank base uplift and sliding over the foundation failure modes were also evaluated on the basis of the effect of anchorage ratio on tanks. The second objective of the research was to examine the impact of friction between the tank base plate and tank foundation on tanks seismic performance. For this purpose, the tank's seismic performance was evaluated by considering two different friction coefficients. The findings of this study contribute new and valuable insights into the existing literature on the seismic performance of unanchored tanks and the effects of anchorage ratio on their seismic performance. In addition, the study provided a better understanding of the effects of unanchored tanks base friction on their seismic performance. Consequently, these findings will contribute to procedures used for seismic design of unanchored tanks and enhance the seismic performance of tanks at highly seismic regions.
Author
İrsen Nihan Kocras
Institution
How to Cite
İrsen Nihan Kocras (Master Thesis). Türkiye'de yüksek sismik bölgelerde bulunan kendinden ankrajlı tankların sismik performansı, 2023, Özyeğin University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Özyeğin University
- A metaheuristic approach for multiple-item economic lot sizing problem with inventory dependent demand(2023)
- İleri karmaşık olay işleme özellikli veri akışı yönetim sisteminin tasarım ve gerçeklemesi(2013)
- Biyolojik kendiliğinden iyileşen çimento esaslı harçların performansa dayalı değerlendirilmesi(2022)
- Effective remorse provisions for drug and stimulant substances crimes in the Turkish Penal Code(2023)
- Bina bölütlemesi ve yükseklik tahmini için görsel durum-uzayı tabanlı çoklu görevli öğrenme(2025)
- Tam ka-bant uydu haberleşmesi için çift dairesel kutuplamalı horn anten ve besleme ağı(2025)
