Load bearing of different fixed prosthesis materials with various cantilever lenghts
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
ABSTRACT Aşkan, İ. (2023). Load Bearing of Different Fixed Dental Prosthesis Materials with Various Cantilever Lengths. Yeditepe University, Institute of Health Sciences, Department of Prosthodontic Dentistry, Phd Thesis, Istanbul. The aim of this in vitro study was to observe structural changes of CAD-CAM polyaryletherketons under load as a cantilever fixed prosthesis framework. Three different types of high performance polymers were milled from CAD-CAM blanks to test, after being cemented on an edentulous scenario [Polyetheretherketon (PEEK) (PE), Polyetherketonketon (PEKK) (PK), Bio High Performance Polymer (Bio-HPP) (BH), Lazer sintered Cr-Co alloy frameworks serve as the control group (CC). Samples have been prepared to create two subgroups by two different cantilevers [14 mm cantilevered samples (PE14, PK14, BH14, CC14) (n=10); 21 mm cantilevered samples (PE21, PK21, BH21, CC21) (n=10)]. Each specimen underwent thermocycle and cemented on the main model with resin reinforced glass ionomer cement. Specimens reciprocated vertical load 2 mm away from the most lateral point of cantilever beam, on Instron Universal Testing Machine 3228, carrying out a load to failure test. Decementation and deformation values have been recorded. The conformity of the parameters to the normal distribution was evaluated by Kolmogorov-Smirnov and Shapiro-Wilks tests. The data was analyzed with two way ANOVA. There was no statistically significant difference between the material groups in terms of decementation and deformation values [(p:0.122 ; p>0.05 and (p:0.337 ; p>0.05)]. There was a statistically significant difference between the cantilever lenghts in terms of decementation and deformation values [(p:0.005 ; p<0.05) and (p:0.001 ; p<0.05)]. Within the limitations of this study, load to failure results can be showm respectively as; BH14, PK14, PE14, PK21, BH21, PE21 (¯x deformation values; ▁(+)288 N, ▁(+)255 N, ▁(+)249,5 N, ▁(+)150,5 N, ▁(+)148 N, ▁(+)131 N). Keywords: Fixed Prosthesis, PEEK, PEKK, Bio-HPP, Cr-Co, Cantilever, CAD/CAM
Author
İlayda Aşkan
How to Cite
İlayda Aşkan (Doctorate thesis). Load bearing of different fixed prosthesis materials with various cantilever lenghts, 2023, Yeditepe University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Yeditepe University
- Studies on cyclodextrin complexation of a poorly water soluble anti-hyperlipidemic drug, tablet formulation and characterization(2021)
- Washington ambassadors in Turkish-US relations (1927-1960)(2023)
- Metamorphosis of female voices: A study of the violation of women in Greek and Roman mythology and feminist rewritings reclaiming the narrative(2022)
- Knowledge distillation with foundation models for image segmentation(2023)
- The relationship between machiavelism, grandiose and vulnerable narcissism, and loneliness among white collar workers(2023)
- Evaluation of drug-drug interaction checkers along clinically relevant adverse drug events in oncology and hematology pediatric patients(2023)