Comparison of different systems for quality assurance applied volumetric arc therapy (VMAT) plans in head and neck cancer
2016
0 views
0 downloads
Advisor: Prof. Dr. Fadime Akman ; Yrd. Doç. Dr. Kadir Akgüngör
Abstract (EN)
Purpose: To compare various dose verification systems used in Volumetric Modulated Arc Therapy (VMAT) in terms of their reliability and applicability with treatment planning system (TPS) on dosimetric aspects. Material and Methods: In this study, the accuracy of VMAT plans, which were prepared by using Eclipse (Varian Medical Systems) TPS, were compared with different (various) dose verification systems for a total of thirty one locally advanced head and neck cancer patiens before their treatment. The VMAT plans were checked with ArcCheck (Sun Nuclear) diode detectors, EPID (Varian Medical Systems) and EPIQA quality assurance (QA) systems using gamma analysis method. The QA plans for each patient were created by placing the gantry, collimator and table angles in the appropriate positions in the Eclips TPS for all QA systems. The plans for each QA systems were irradiated with TrueBeam. Dose maps were obtained with irradiation. Dose difference was 3%, whereas distance to agreement was 3 mm selected for comparison QA systems. Statistical analyzes were performed using SPSS Version 24 program Correlation analysis and Sample Paired T-test. Results: The average results of ArcCheck, EPID and EPIQA using gamma analysis method compared with TPS was observed as %98,41 (94,9-100) (±1,700), %99,70 (98,6-100) (±0,329), %96,78 (86,7-99,32) (±2,893) , respectively. According to gamma analysis results, two of the measurements made with ArcCheck and EPIQA did not pass acceptance limit (%95), but ArcCheck's measurement results too close to acceptance limit (%95). Besides this, all of the measurements made with EPID are above the 95% acceptance limit. The r values obtained by Correlation analysis were 0,506 for compared ArcCheck and EPID, 0,132 for compared EPID and EPIQA, 0,203 for compared ArcCheck and EPIQA. Conclusion: ArcCheck and EPID devices can be used interchangeably when comparing the measurement results of the qualitative reliability systems of the VMAT plans in the local advanced head and neck cancer with the Sample Paired T test and the Correlation test. Key Words: head and neck cancer, VMAT, quality assurance systems, gamma analysis
Author
Dr. Pelin Taymaz
How to Cite
Pelin Taymaz (Master Thesis). Comparison of different systems for quality assurance applied volumetric arc therapy (VMAT) plans in head and neck cancer, 2016, Bingol University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Bingol University
- Analysis of the relationship among work engagement, work locus of control, passion and parasites in hotels(2017)
- Analysis of the expectations and experiences of women visiting the Imam-ı Birgivi Shrine in the scope of religious tourism(2017)
- The effect of the flexibility of CNC machines on the precision of orthotic insole manufacturing(2017)
- Cost accounting in hospital and a pravite hospital application(2017)
- Analysis of the solo Sonata no.1 by Johann Sebastian Bach in terms of periodic, structural and technical(2017)
- The effects of oleuropein and cisplatin on neuroblastoma cells(2017)