Comprasion of new design suture removal device and classic suture removal devices
2014
0 views
0 downloads
Advisor: Prof. Dr. Ali Doğan Bozdağ
Abstract (EN)
Introduction: Wound healing became the primary field of occupation for researchers. Some inflammatory cases occur not only during stitching, but also in course of suture receiving. We designed a new device that is both easy to implement and promotes suture receiving without harming the wound site; and took out a patent for it. We tried to prove the functionality of our new suture receiver device through an animal experiment. Material Method: 14 Sprague-Dawley type rats were included in the study in total. They were classified as two groups. The sutures of 7 rats in the first group were received by the new design suture receiver device, while the sutures of 7 rats in the second group were received by forceps and lancet, which is the classic method. The preparation of experimental animals, wounding and wound care technique, the weights of rats, suture receiving rates and wound site histopathologies were evaluated statistically. Findings: A significant difference was not found with regards to weights of rats (p 0,652). The statistical difference between the new device and the classic method was not significant when suture receiving times were examined (p<0.05). When the damages created in tissues as the sutures are received by these two methods are evaluated microscopically, it was determined that any tissue damage was not occurred in both techniques (p=1,000). And a significant difference was not seen for both techniques, when the damages they created in tissues were compared microscopically. Result: In our study, it became possible to compare a new device and the traditional method and devices that are used for hundreds of years. When viewed from this aspect, it is important with regards to leading similar studies. Using the new device not only provide advantage with regards to both time and performance, but also formed an impression that it will be easier to receive troublesome sutures. The speedup observed as we keep using the new device encourages us for the device to come into practical use. Key words: Suture removal, wound healing
Author
Dr. Ethem Bilgiç
How to Cite
Ethem Bilgiç (Medical Specialty Thesis). Comprasion of new design suture removal device and classic suture removal devices, 2014, Adnan Menderes University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Adnan Menderes University
- Determination of helminth species and prevalence of the fish of the Bafa Lake(2014)
- Synthesis and characterization of carboxylic acid derivatives of boranes(2013)
- Novel square esteramide compounds(2013)
- Development of intermediary institutions and the components effecting investors' choice of intermediary institutions: An application of factor analysis(2013)
- Ultrasonographic evaluation of intra-abdominal lesions in dogs(2013)
- Türk sağlık reformları kapsamında sağlıkta dönüşüm programının incelenmesi(2013)