Friction Stir Spot Welding of Aluminium Alloy AA5052 With and Without Carbon Fiber-reinforced Polymer Composite Interlayer
2021
0 görüntülenme
0 i̇ndirme
Danışman: Babak (Supervisor) Safaei
Özet (EN)
In this dissertation, similar aluminum alloys AA5052 with additional carbon fiber reinforced polymer composite (CFRP) interlayer were selected to investigate the effect of welding parameters (rotational speed and dwell time) on the mechanical properties, joint efficiency, and microstructure of friction stir spot weld joint. The maximum tensile shear load was 1779.6 N with joint efficiency of 14.6% obtained at rotational speed of 2,000 rpm and 2 s dwell time, which is 39.5% higher than the value at low rotational speed 850 rpm and 2 s dwell time whereas the joints without interlayer the maximum tensile shear load was 2439 N with joint efficiency of 19.4% obtained at 1300 rpm and 2 s dwell time, which is 48% higher than the value at low rotational speed 850 rpm and 5 s dwell time. Meanwhile, the maximum microhardness 58 HV was attained in the keyhole region at rotational speed of 2,000 rpm and dwell time of 5 s, which is 22.4% higher compared to low rotational speed. On the other hand the specimens without carbon fiber interlayer, the maximum microhardness was 37.2 HV was obtained at 850 rpm and 2 second dwell time in thermal mechanical affect zone, which is about 51% higher compared to low rotational speed. The SEM-EDS results reveal the presence of intermetallic compounds (Al–Mg–C), which enhance the intermetallic bonding between elements. The microstructure without interlayer images showed that welding parameters such as rotational speed and dwell time have high effect on hook deformation and penetration around the pin area. It was proposed a novel prediction model to predict tensile shear load of samples with and with CFRP interlayer by applying various machine learning models i.e. artificial neural network (ANN), Adopted neuro fuzzy-inference system (ANFIS), support vector machine (SVM) and multi linear regression (MLR). According to test results, it has an incentive effect for future studies to know that MLR model produce better results to estimate tensile shear load in both cases of with and without additional interlayer rather than the other model and the average error was just 0.333% and 3.64 % respectively.
Yazar
Dr. Omer Kalaf
Bu Yayına Nasıl Atıf Yapılır
Omer Kalaf (Doctorate thesis). Friction Stir Spot Welding of Aluminium Alloy AA5052 With and Without Carbon Fiber-reinforced Polymer Composite Interlayer, 2021, Eastern Mediterranean University, Department of Mechanical Engineering.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Eastern Mediterranean University tezlerinden daha fazlası
- An Investigation on Time and Cost Overrun in Construction Projects(2012)
- Radial Power-Law Position-dependent Mass, Cylindrical Coordinates, Spectral Signatures(2015)
- Predicting performance level of reinforced concrete structures subject to corrosion as a function of time(2012)
- Discussion of Conservation Approaches for the Selected Heritage Buildings in the Walled City of Famagusta(2019)
- High School Students' Learning Styles in North Cyprus(2011)
- Afyonkarahisar İl Merkezinde Yaşayan 18 Yaş ve Üzeri Kadınların Diyet Posasıyla İlgili Bilgi Düzeylerinin ve Posa Alım Miktarlarının Belirlenmesi(2018)
