Improving the quantification accuracy of Tc-99m mibi dual-phase parathyroid SPECT/ct: Amonte carlo simulation study
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Objective: Quantitative parathyroid SPECT imaging is a technique used to assess primary hyperparathyroidism that may have potential in the identification and differentiation of parathyroid lesions as well as the estimation of disease severity. Studying the effect of data acquisition parameters on the quantification error is important for maximizing the accuracy of this diagnostic technique. In this study, we examine the effects of different data acquisition parameters, namely the type of collimator, scatter correction status, and reconstruction iteration number on the quantification accuracy using computer simulation. Methods: The SIMIND Monte Carlo Simulation and CASToR iterative reconstruction program was used to simulate a commercially available SPECT camera (Siemens Symbia Intevo Gamma Camera) with a crystal size of 29.55cm and 128x128 matrix size. A digital cylindrical phantom filled with water was constructed. A 0.36 cm radius spherical adenoma filled with a uniform 1MBq/cc Tc99m-Sestamibi was placed within the phantom. Low-Energy High Resolution (LEHR) and Low Energy Ultra High Resolution (LEUHR) collimator models are tested. Along with the presence of Scatter correction and differing iteration numbers (x16, x32). An image FOV-based calibration method was used to gather quantitative information and check against the input radioactivity. Results: The presence of scatter correction caused a 15-20 percent relative improvement in quantification accuracy. The optimal number of iterations produced a 10 percent relative improvement. Overall, accuracies as good as 7 percent in estimated activity concentration could be observed. Conclusion: The optimization of parameters can provide a significant improvement in quantification accuracy.
Author
Bahadır Aytaç
How to Cite
Bahadır Aytaç (Master Thesis). Improving the quantification accuracy of Tc-99m mibi dual-phase parathyroid SPECT/ct: Amonte carlo simulation study, 2023, Boğaziçi University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Boğaziçi University
- Investigating the factors affecting the acceptance of generative artificial intelligence in business intelligence applications(2025)
- Nükleer güç, emek ve çevre: Akkuyu NGS(2023)
- Behind the gallows: Capital punishment, law, and legislative performance in Turkey (1926-1990)(2025)
- Exploring the values for nature, nature connectedness, pro-environmental behaviour, and well-being: A case study on urban park visitors in Istanbul(2025)
- An assessment on the role of regional development agencies in environmental governance in Türkiye: A case study on Thrace Region(2025)
- Political ecology of milk production in Türkiye: Changing practices, rural livelihoods, and dairy animals(2025)