Investigation of the fire performance of steel column-beam joints with and without fire protection
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
In this study, the performance of steel column-beam joints against fire is investigated in protected and unprotected conditions. The effectiveness of intumescent paints as a passive protection method was experimentally evaluated by finite element method. During fire, steel elements lose their strength, especially at temperatures such as 600°C, jeopardizing the bearing capacity of structures. Intumescent paints form a protective layer on the steel surface by expanding in fire and increase resistance to high temperatures. Experimental tests were carried out on coated and untreated steel specimens and the results showed that intumescent coatings are effective in increasing the fire resistance time. The research aims to contribute to the development of building design and fire safety standards and to safeguard human lives by facilitating evacuation processes.
Author
Adem Şafak
How to Cite
Adem Şafak (Master Thesis). Investigation of the fire performance of steel column-beam joints with and without fire protection, 2024, Erzurum Technical University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Erzurum Technical University
- Investigation of the therapeutic effi̇cacy of chitosansilver nanoparticle-loaded doxorubicin on liver cancer cells(2025)
- Education in the Mardin Sanjak from Tanzimat to Republic(2015)
- Evaluation of neuroprotective effects of boron nitride nanoparticles in the experimental Parkinson model(2019)
- The structure and theme in the novels by Sema Kaygusuz(2020)
- Investigation of the relationship between cyberchondria and health anxiety in university students(2024)
- Transcribed text and analysis of The National Library's Poetry Macmua No. 06 Yz A 1879(2025)