The evaluation of the ftacture strenght of different esthetic abutment after cyclic fatique loading
2015
0 views
0 downloads
Advisor: Prof. Dr. Aslıhan Üşümez
Abstract (EN)
The aim of this study was to compare the fracture strength of peek abutments and zirconium abutments which are widely preferred instead of titanium abutments in the esthetic zone for the implant supported fixed prosthesis. In this study, the fracture strength of zirconium and peek abutments were compared after aging by chewing simulator. Study groups were; Group 1: 10 zirconium abutments on the implants (Bredent, Germany, 12 mm length and 4 mm diameter) , Group 2: Peek abutments on the implants (Bredent, Germany, 12 mm length and 4 mm diameter). All implants are embeded into an acrylic resin (Paladent-Kulzer) with 45° angle and torqued with 25 N to the implants. Afterwards, zirconia cores (Zenostar T2 Wieland) were cemented with temporary implant cement (Premier; ABD). Fatique test was performed with a chewing simulator for 1,2 million cycles. Subsequently, load to fracture test was applied by a loading device (Shimadzu, Japan) to all specimens with a speed of 1mm/ min. The fracture strength values were 478,83± 66,72 N for peek abutment group and 722,50± 84,71 N for zirconium abutment group. The results were statistically analysed with T-test. The fracture strength of zirconia abutments were statistically significantly higher than peek abutments (p< 0,001). Key words: Zirconia, ceramic, peek, abutment, fracture strength
Author
Berna Balcı
Institution
How to Cite
Berna Balcı (Master Thesis). The evaluation of the ftacture strenght of different esthetic abutment after cyclic fatique loading, 2015, Bezmialem Vakıf University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Bezmialem Vakıf University
- Assessment of micro RNA level of patients diagnosed with tuberous sclerosis(2016)
- Açık teknik septorinoplasti yapılan olgularda postoperatif bantlamanın ödeme etkisi(2015)
- Adölesan dönemde hirşutizm tanısı alan hastalarda etyolojik dağılım(2015)
- Diagnostic value of signal peptide complement C1R/C1S, UEGF, and BMP1 epidermal growth factor like domain containing protein in unstable angina pectoris patients(2015)
- The effect of high mobility group box-1 protein on cerebral edema, blood-brain barrier, oxidative stress and apoptozis in traumatic brain injury(2016)
- 5-fluorourasile bağlı arteryel vazokonstrüksiyon etyolojisinde ürotensin-2'nin rolü(2017)