Determination of the correlation between invasive intracranial pressure values measured via external ventricular drainage catheters and non-invasive intracranial pressure values measured by transcranial doppler USG in patients with increased intracranial pressure in intensive care units
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Objective: We aim to determine the correlation between the invasively measured intracranial pressure and the non-invasively calculated intracranial pressure using transcranial doppler ultrasonography in patients with external ventricular drainage catheters in neuro-intensive care units. Materials and Methods: A total of 905 simultaneous invasive and non- invasive intracranial pressure (ICP) measurements, collected from 50 patients between February 1, 2023, and August 1, 2025, at the Intensive Care Units of Istanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Department of Anesthesiology and Reanimation, were evaluated prospectively and observationally. Results: A statistically insignificant and very weak correlation was found between invasive ICP and non-invasive ICP measurements (r = 0.012, p = 0.710). The mean difference (bias) between the two measurements was calculated as -17.12 mmHg. The limits of agreement were found to be considerably wide (-62.83 to +28.58 mmHg). This indicates high individual variability between the two methods and a lack of clinical consistency. While a moderate, positive, and significant correlation was observed between non-invasive ICP and mean arterial pressure (r = 0.476, p = 0.000), a weak and negative correlation was found between invasive ICP and mean arterial pressure. Conclusion: These findings suggest that transcranial Doppler ultrasonography parameters are not an alternative to invasive methods for monitoring intracranial pressure. However, they may be utilized solely as a supportive monitoring method in cases where invasive measurement is unfeasible or carries high risk Keywords: intracranial pressure, transcranial doppler ultrasonography, external ventricular drainage, resistive index, pulsatility index
Author
Seher Budak
How to Cite
Seher Budak (Medical Specialty Thesis). Determination of the correlation between invasive intracranial pressure values measured via external ventricular drainage catheters and non-invasive intracranial pressure values measured by transcranial doppler USG in patients with increased intracranial pressure in intensive care units, 2025, İstanbul University-Cerrahpaşa.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from İstanbul University-Cerrahpaşa
- Reinterpreting the street as a field of work from the perspective of social work in türki̇ye: A field study in the case of istanbul(2024)
- Developing 3D printer for thermoelectrical material and module fabrication(2024)
- The effect of mentoring programme on reality shock, clinical adaptation and professional competencies of new graduated nurses(2024)
- Evaluation of the effectiveness of safe nutrition program applied to acute stroke patients with dysphagia(2024)
- Joint inversion of H/V and SPAC methods: A case study of Eskişehir Basin(2024)
- Nurses' views on motivation and development of the nurse motivation scale(2024)