68Ga-PSMA-11 preparation and radiochemical purity analysis via quality by design (QBD) principles
2019
0 views
0 downloads
Advisor: Doç. Dr. Sena Çağlar Andaç ; Doç. Dr. Emine Meltem Ocak Demirci
Abstract (EN)
68Ga-PSMA-11 radiopharmaceuticals have been widely used in recent years for PET/CT imaging of prostate cancer recurrence and metastases. Synthesis conditions may affect radiolabeling quality and in vivo behavior and no standard procedure for the quality control (QC) is available. In this study, it is aimed to determine the critical process parameters of 68Ga-PSMA-11 synthesis via QbD approach, and to optimize 68Ga-PSMA-11 synthesis via experimental design programs. In addition, since European Pharmacopoeia have no respective guidelines on the QC of 68Ga-PSMA-11, it is aimed to develop and validate analytical method for determination of radiochemical and chemical purity. Critical process parameters (CQA) and experimental design (DoE) for 68Ga-PSMA-11 synthesis optimization were identified based on literature review. DoE was statistically designed using Design Expert software version 10.0. Response surface modelling (RSM) was applied to estimate the relationship between the independent factors and CQAs. Validation of the analytical method for the determination of chemical and radiochemical purity of 68Ga-PSMA-11 was carried out according to ICH Q2 (R1) guidelines. As a result a new selective and sensitive high-performance liquid chromatography method for chemical and radiochemical purity testing of 68Ga-PSMA-11 has been developed and validated. The linearity between 0.5-15 μg / mL was found R2 ≥ 0.99 and % RSD value was found <2. As a result of the optimization study carried out by using Design Expert 10.0.0 software, the reaction temperature was 95 C, the reaction time was 220 sec, reaction pH 4.40 and the amount of PSMA-11 was 10 μg / mL. Key Words: 68Ga-PSMA-11, Quality by Design, Optimization,Radiopharmaceutical The present work was supported by the Research Fund of Istanbul University. Project No. TYL-2019-33814
Author
Dr. Hüseyin Pehlivanoğlu
How to Cite
Hüseyin Pehlivanoğlu (Master Thesis). 68Ga-PSMA-11 preparation and radiochemical purity analysis via quality by design (QBD) principles, 2019, İstanbul University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from İstanbul University
- In the covid 19 pandemic of female employees at a university hospital attitudes and affecting factors in nutrition of 9 months-6 years old children(2022)
- The perception of the right-wing movements in Turkey as to the 27 May Coup: 1960-1980(2020)
- Economic and social life in the Ottoman Empire according to the 1890 year's news of La Turquie Newspaper(2022)
- Land regime in the Umayyads period(2022)
- Merkel hücreli karsinomda tanısal ve prognostik belirteçler(2022)
- Biotechnologically production of polyethylene terephthalate (PET) type plastic degrading enzyme petase in escherichia coli(2021)