Comparison of intensity modulated radiation therapy (IMRT) vs. intensity modulated arc therapy (IMAT) in head-and-neck cancer radiotherapy
2012
0 görüntülenme
0 i̇ndirme
Danışman: Prof. Dr. Enis Özyar
Özet (EN)
In this study, 5, 7, 9 field IMRT and 1 and 2 arc IMAT plans were performed for 12 patients with head and neck cancer. Plans were normalized to improve % 95 PTV coverage. PTV and critical structure maximum and mean doses were analyzed by using DVH. Comparisons were made among IMRT and IMAT priorities; 5, 7 and 9 field IMRT plans; 1 and 2 arc IMAT plans; 7 field IMRT and 2 arc IMAT plan. Higher doses to PTV for plans with IMRT priorities and to critical structures for plans with IMAT priorities were seen. When a comparison were made between 5, 7 and 9 field IMRT plans, higher doses were seen for 5 field IMRT. The most homogeneous dose distributions were seen for 7 field IMRT plans. Higher doses were seen for 1 arc IMAT plans, compared to 2 arc plans. When IMRT and IMAT plans were compared, higher doses were seen by 2 arc IMAT plans. As body contour inhomogeneities are more effective for IMAT plans which use whole body contour compared to fıxed gantry fields used at 7 field IMRT plans. IMRT plans use more MU in proportion to the number of fields. IMAT plans show significantly lower number of MU. There is no significant increase between MU values of 1 and 2 arcs. However, 2 arc IMAT plans have more homogeneous dose distribution and lower critical structure doses compare to 1 arc plan.
Yazar
Dr. Mine Doyuran
Bu Yayına Nasıl Atıf Yapılır
Mine Doyuran (Master Thesis). Comparison of intensity modulated radiation therapy (IMRT) vs. intensity modulated arc therapy (IMAT) in head-and-neck cancer radiotherapy, 2012, Acıbadem University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Acıbadem University tezlerinden daha fazlası
- The effect of exogenous oxytocin on streptozotocin (STZ)-induced diabetic adult rat testes(2012)
- Comparison of doses calculated by anisotropic analytical algorithm and pencil beam convolution in the inhomogeneous tissues(2012)
- Assessment of interfraction set-up uncertainties according to different anatomical regions with kV-kV IGRT for head-and-neck radiotherapy(2012)
- Comparison of cyberknife and gammaknife treatment plans for target volume and normal tissue doses(2012)
- Comparison of octavius phantom with EpiQA portal dosimetry software for patient based quality control of vat(2012)
- Comparison of PDIP and glaas algorithms used in quality control with portal dosimetry of intensity modulated radiotherapy plans(2012)