Experimental study of effects of electrical arc furnace on electric network and computer aided modeling
2017
0 views
0 downloads
Advisor: Prof. Dr. Arif Memmedov
Abstract (EN)
During the recent years, with its increasing steel production, Turkey has succeeded becoming one of the ten biggest steel producer countries in the world. In Turkey, approximately 71.3% of the steel produced in Turkey is producing with the help of Electric Arc Furnace (EAF) facilities. EAF's have significant advantages such as high melting and low production costs. However, due to their nonlinear characteristics, they cause significant power quality problems in electrical networks. In this study, the power quality problems caused by 60 MVA EAF load, which is located in SİDEMİR facility, have been experimentally investigated. Harmonic effects have been evaluated with the help of the Electromagnetic Transient Program (EMTP) using a phase equivalent of the electrical system feeding the EAF load. Suggetions to improve of the power quality problems caused by EAF 60 have been presented by comparing experimental measurement results and EMTP analyzes. Suitability of the time-domain arc models which has been presented in literature for the definition of electrical arc have been examined with the arc characterization obtained from the experimental data and the curve fitting methods using Matlab Curve Fitting Toolbox and a new time domain arc model have been developed to identify the electrical arc for EAF's. It is seen that the developed new time domain model describes the operating characteristics of EAF furnaces better than the models presented in the literature. It has been shown that the three-phase simulation model using this arc model can be used with high accuracy to identify power quality problems caused by the EAF. As a result of the experimental studies carried out and the simulation done it has been identified that SVC systems cause even harmonics, and serial reactor application is not suitable for the current system. The transformers must be protected with differential differential relay and It has been determined that when synchronous compensation and SVC compensation are used together, voltage harmonics occurring at the beginning of melting can be reduced. According to the probability theory, current and voltage deviations smaller than 5% in the present network.
Author
Dr. Mustafa Şeker
Institution
How to Cite
Mustafa Şeker (Doctorate thesis). Experimental study of effects of electrical arc furnace on electric network and computer aided modeling, 2017, İnönü University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from İnönü University
- Knowledge, opinions and applications of pediatric nurses towards therapeutic games(2017)
- The effects of systemic pistacia eurycarpa yalt administration on alveolar bone loss and oxidative stress in rats with experimental periodontitis(2021)
- The effect of motivational interviews for primiparous pregnant women with low normal birth belief on medical and natural birth belief(2022)
- Retrospective investigation of genetic etiology in pediatric epilepsy patients based on targeted next generation sequence analysis datas(2022)
- The commentary methodology in the commentary on al-Fath al-Mubyn bi-Sharh al-Arba'eyn by Ibn Hajar al-Haytamy(2022)
- Comparison of serum BDNF, S100B levels of patients with bipolar disorder in manic and remission periods with healthy volunteers and evaluation of results with neuropsychological tests(2022)
