Experimental Investigation of the Effect of Absorber Plate Temperature on Double Slope Inclined Solar Water Desalination Still

2014
0 görüntülenme
0 i̇ndirme
Danışman: Mustafa (Co-Supervisor) İlkan

Özet (EN)

Solar energy can be used for potable water production from brackish water. In this study the effect of the absorber plate temperature on the inclined solar water desalination having double sloped cover (DS-ISWD) performance was experimentally studied. The DS-ISWD system with net cavity area of 1.5 m2 was constructed and it has two slope glazing; each inclined 250 and four spray jet nozzles were installed at equal intervals within the DS-ISWD. The experience gained form the operation of spray jet solar desalination at the Eastern Mediterranean University, N. Cyprus has revealed the importance of feeding water volume on the system performance. The DS-ISWD system with four jet sprays was tested with different on set temperatures of 40, 45, 50, 55, 60o C in spring (April). The maximum daily yield achieved was 3.85 kg/day m2 when the absorber plate temperature was kept at 55oC. The fresh water yield at 40, 45, 50, 55, and 60oC absorber plate temperatures were 3.6, 3.71, 3.72, 3.85 and 3.68 kg/day m2 respectively. It was observed that when the onset temperature was set 65oC the pump was not in operation after 14:00 hrs. This indicates that the absorber plate temperature was less than 65oC so the system stops generating fresh water after 14:00 hrs. Therefore, the 65 oC plate temperature was ignored in spring tests. The daily average efficiency of DS-ISWD system was observed to be 33.8% for 55oC set-point temperature. The effect of continuous water spraying on the DS-ISWD productivity was also examined. When the absorber plate was at 40oC the pump operated continuously i.e., the feedwater was continuous. The experiments were also conducted in July and the optimum absorber temperature was found to be 65oC with 4.2 kg/day m2 of fresh water production. At 60oC the pump operated continuously and the fresh water production was 5% less than the optimum whereas, the production was decreased by 5% when the absorber plate was at 70oC. From the obtained results it can be concluded that the performance of the DS-ISWD depends on the absorber plate temperature. The DS-ISWD performance also depends on the solar insolation, feedwater temperature, sprayed water size and other climatic parameters. Keywords: Potable water, inclined solar water desalination, absorber plate temperature, thermal efficiency

Yazar

Dr. Maziar Salimizad

Bu Yayına Nasıl Atıf Yapılır

Maziar Salimizad (Master Thesis). Experimental Investigation of the Effect of Absorber Plate Temperature on Double Slope Inclined Solar Water Desalination Still, 2014, Eastern Mediterranean University, Department of Mechanical Engineering.

Lisans

Tüm Hakları Saklıdır

Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.

Eastern Mediterranean University tezlerinden daha fazlası