Kesimli 2D RF eksitasyon ile gürbüz yüksek çözünürlüklü indirgenmiş görüş alanlı MRG
2022
0 views
0 downloads
Advisor: Doç. Dr. Emine Ülkü Sarıtaş Çukur
Abstract (EN)
Reduced field-of-view (FOV) single-shot echo-planar imaging (ssEPI) is a widely applied imaging technique for diffusion-weighted magnetic resonance imaging (MRI), due to its robustness against in-plane off-resonance artifacts. Two-dimensional echo-planar RF (2D RF) excitation is a popular approach for reduced-FOV imaging due to its fat suppression capability and sharp slab profiles. However, long pulse durations render 2D RF pulses sensitive to through-plane off-resonance effects, causing local signal losses in reduced-FOV images. The standard 2D RF pulses also generate excitation replicas along the slice stack, limiting the slice coverage during multislice imaging. This thesis proposes a sheared 2D RF design for reduced-FOV imaging for significant reduction in pulse duration, leading to significant improvement in through-plane off-resonance robustness. The proposed design also provides unlimited slice coverage and high fidelity fat suppression. Sheared k-space trajectories are designed such that the excitation replicas are positioned outside the slice stack to guarantee unlimited slice coverage, while ensuring identical k-space coverage as that of a standard 2D RF pulse. The efficacy of the sheared design is demonstrated by extensive simulations in terms of pulse duration, fat suppression capability, and signal comparisons under off-resonance effects for a range of design parameters and hardware limits. The sheared and standard 2D RF pulses are then compared via imaging experiments on a custom head and neck phantom, and in vivo imaging experiments in the spinal cord at 3 T. The results show that in regions with high off-resonance effects, the sheared 2D RF pulse improves the signal by more than 50\% when compared to the standard 2D RF pulse while preserving profile sharpness. Lastly, the benefits of the sheared design are demonstrated for low-cost low-field MRI systems via simulations and phantom experiments, making reduced-FOV imaging applicable on these systems. The proposed sheared 2D RF design will be especially beneficial in regions suffering from a variety of off-resonance effects, such as spinal cord and breast.
Author
Dr. Bahadır Alp Barlas
Institution
How to Cite
Bahadır Alp Barlas (Master Thesis). Kesimli 2D RF eksitasyon ile gürbüz yüksek çözünürlüklü indirgenmiş görüş alanlı MRG, 2022, Bilkent University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Bilkent University
- Geç Antik Çağ'da Aşağı Tuna: Histria örneği(2023)
- Petrol fiyatları ve getiri eğrisi(2024)
- Sözle yönlendirme üzerine makaleler(2014)
- İletişim ağları ve sağlık uygulamaları için çok kollu haydut algoritmaları(2022)
- Türk Anayasa Mahkemesinin içtihatları ışığında karşılaştırmalı anayasal mutluluk(2023)
- Doğrusal karbon zincirlerinin yoğunluk fonksiyoneli teorisi ile incelenmesi(2023)
