Master'sOpen Access

Comparison of the results obtained by pushover analysis and seismic index method for existing buildings

2006
0 views
0 downloads
Advisor: Yrd. Doç. Dr. Ali Ergün

Abstract (EN)

Last eartquakes indicate that, many existing structures in Turkey do not havesufficent seismic safety. Workings began to determine the building? seismic safety.It?s practically impossible to examine all buildings by detailed structural analysis.So, it?s necessary to determine the seismic safety of buildings with a quickevaluation method. It?s inevitable to utilize a quick evaluation method for decidingwhich buildings need further detailed structural analysis, and which buildings canbe used with their existing seismic safety levels.In this study, three reinforced concrete buildings are examined with PushoverAnalysis, considering the seismic desing loads by the Turkish Eartquake ResistantDesign Code and to compare Japanese Seismic Index Method, which is betweenthe most accepted quick seismic safety evaluation.2006, 132 pagesKey Words: Reinforced Concrete Buildings, Pushover Analysis, Japanese SeismicIndex Method, SAP2000.

Author

Dr. Veli Başaran

How to Cite

Veli Başaran (Master Thesis). Comparison of the results obtained by pushover analysis and seismic index method for existing buildings, 2006, Afyon Kocatepe University.

Keywords

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.