Microcantilever based sensor for characterization of ethanol-CO2 fluid mixtures at high pressures
2018
0 views
0 downloads
Advisor: Prof. Dr. Alphan Sennaroğlu ; Prof. Dr. Can Erkey
Abstract (TR)
Determination of composition of ethanol-CO2 mixtures at high pressures is important in many applications involving supercritical fluids such as drying of alcogels or release of microelectromechanical device. Viscosity of ethanol-CO2 mixture is also important in many applications and processes, for example, to understand the dynamics of supercritical antisolvent (SAS) and supercritical anti solvent precipitation inside the pores (SASIP) processes, to design and optimize supercritical fluid based processes, to calculate Reynolds and Schmidt numbers, and to estimate diffusion coefficients of ethanol-CO2 mixtures from available correlations. Frequency response of an oscillating microcantilever immersed in a fluid mixture can be used to determine the composition and viscosity of the mixture over a wide range of temperatures and pressures. The resonant frequency and quality factor (Q-factor) of ferromagnetic nickel microcantilevers immersed in ethanol-CO2 mixtures were measured in a temperature range of 308 – 333 K and pressure range of 7 – 33 MPa. The measurements were carried out with a custom built experimental setup consisting of a high-pressure vessel with temperature and pressure control, a coil for magnetic actuation of the immersed cantilevers, and a quadrant photodetector for optical readout of the cantilever displacement. In this dissertation, four types of studies were performed with the frequency response measurements of cantilevers: (i) Mixture composition determination of ethanol-CO2 mixtures, (ii) Compositional measurement sensitivity of cantilevers, (iii) Viscosity measurement of mixtures, and (iv) Viscosity measurement sensitivity of cantilevers. The frequency response of cantilevers immersed in ethanol-CO2 mixtures containing 0.0091 – 0.0616 weight fraction of ethanol were measured at 308 K and within the pressure range 8 – 22 MPa. The resonant frequencies and Q-factors were found to decrease in a smooth manner with the increasing weight fraction of ethanol in the mixture. At a constant temperature, the sensitivity of resonant frequency to changes in fluid composition was found to increase with decreasing pressure. The experimental results showed that ethanol-CO2 mixture composition can be determined with good accuracy at high pressures using mainly the measured resonant frequency of microcantilevers. The considerable changes in the resonant frequency as a function of different compositions suggested that this approach can potentially be used in the supercritical drying process for aerogel production to measure ethanol concentration at the exit of the extractor as a function of time and enable the determination of the end of the drying process. Compositional measurement sensitivity of cantilevers defined as the derivative of the cantilever resonant frequency or quality factor with respect to the fluid mixture composition was studied. On the basis of Sader's model of hydrodynamic interaction of an oscillating immersed cantilever with the surrounding fluid, analytical expressions were derived for the sensitivity that were found to be complex functions of the density and viscosity of the mixture as well as the length, width, thickness, and density of the cantilever. Frequency response of cantilevers immersed in ethanol-CO2 mixtures containing 0 – 0.04 weight fraction of ethanol were measured at 318 K and within the pressure range 10 – 21 MPa. Using the measured resonant frequency and quality factor together with previously published density and viscosity data for ethanol-CO2 mixtures of various compositions, the sensitivity at each pressure and temperature was calculated and the LOD was determined. In particular, with our current setup, the LOD ranged from 0.0009 to 0.0071 weight fraction of ethanol in the mixture in the pressure range 10 – 21 MPa for a 150 µm long cantilever. The results convincingly illustrated the potential of miniature cantilever-based probes for fast and sensitive in-situ detection of the composition of fluid mixtures in practical technological processes carried out at high pressures. In addition, new experimental data for the viscosity of ethanol-CO2 mixtures of different compositions with ethanol weight fraction ranging from 0.290 to 0.882 were obtained. The experiments were carried out in the single phase region at a temperature range of 308 to 333 K and a pressure range of 7 to 33 MPa. Viscosity of ethanol-CO2 mixtures were measured using frequency response of an oscillating microcantilever immmersed in the mixture. The viscosity of the mixture increased with increasing ethanol weight fraction at a particular temperature and pressure. At a particular ethanol weight fraction, the viscosity decreased with increasing temperature at a constant density. Refutas equation could predict the viscosities of mixtures successfully that had an ethanol weight fraction greater than 0.29. Lastly, viscosity measurement sensitivity of cantilevers defined as the derivative of the cantilever quality factor with respect to the viscosity of fluid mixture was studied. Analytical expression for the sensitivity was derived based on Sader's model. Using the frequency response data of cantilevers immersed in ethanol-CO2 mixtures containing 0.290 – 0.882 weight fraction of ethanol at a temperature range of 308 – 333 K, together with density and viscosity data of mixtures of various compositions, the model sensitivity was determined at each mixture composition. The model sensitivity was compared with the experiment sensitivity and the relative differences were calculated. The resolution of the cantilever-based viscosity measurements was determined using the experimental sensitivity and the average standard deviations of the Q-factor at a particular mixture composition. The results indicate that with the current setup, the resolution ranged from 2.69 to 12.46 µPa.s. The results show that cantilever-based sensors can be used as viscometers for the viscosity measurement of fluid mixtures in practical technological processes carried out at high pressures.
Author
Dr. Shadı Khan Baloch
How to Cite
Shadı Khan Baloch (Doktora Tezi). Microcantilever based sensor for characterization of ethanol-CO2 fluid mixtures at high pressures, 2018, Koç University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Koç University
- International marketing strategies of Ekom-Eczacıbaşı in the Russian market(1995)
- The Balkans in an Age of Baroque transformations in architecture, decoration, and patterns of patronage ad cultural production in Ottoman Europe, 1718-1856(2006)
- Single machine scheduling with timelag constraints(2014)
- Ottoman olfactory traditions in a palatial space: Incense burners in The Topkapi Palace(2015)
- The connectedness of the Rum Seljuks and the Kingdom of Georgia: A framework for artistic exchance in the thirteenth century(2015)
- Turkish coffee fortune-telling ritual as a source of inspiration for designing object-mediated advice interactions(2017)
