Minyatür bir kan pompasının tasarımı analizi ve geliştirilmesi
2018
0 views
0 downloads
Advisor: Prof. Dr. İsmail Lazoğlu
Abstract (EN)
Congenital Heart Disease (CHD) is one of the leading cause of infant death around the world. According to American Heart Association (AHA) 9.3 out of 1000 live births in Asia are affected from CHD. In adults, Mechanical Circulatory Support (MCS) has emerged as a life-saving device. Due to size limitations and nature of CHD, the adult devices are not suitable for pediatric patients. Thus, there is a need for a miniature MCS device implantable to pediatric patients. This study aims to develop a novel blood pump for CHD patients. The device proposed in this thesis is a novel shrouded impeller axial flow pump. This type of design has never been tried experimentally in blood pumps before. The impeller and diffuser blade angles of blood pump were obtained by performing 2D velocity triangles analysis. Computational Fluid Dynamics (CFD) analysis has been used to predict the hydraulic performance and to visualize the flow field within the pump. A number of impeller and diffuser designs with varying geometric parameters were analyzed to come up with the Prototype I of shrouded impeller pediatric ventricular assist device (SIP-VAD). Regions of high shear stress indicated the possible areas causing blood damage. A benchtop model of Prototype I was manufactured to verify the CFD results. The impeller, inducer, and diffuser were manufactured using rapid prototyping method. Arc-shaped magnets were installed at the outer periphery of the impeller and 3-phase, brushless direct current (BLDC) motor principle was used to rotate the impeller. Comparison of experimental and CFD results revealed the reliability of the CFD model for further design modification. CFD based blood damage analysis was performed using Eulerian stress and strain-based models. The verification of this model was performed by comparing results with the in vitro blood test. Different power law functions were used to find the best model for our design. Results show the strain-based model to be more accurate in predicting blood damage. Based on this model design improvements were made in Prototype I. Further CFD analysis was performed to finalize Prototype II design. The benchtop experimental setup was manufactured using high precision 5-axis machine tool. The in vitro hydraulic and blood test were performed. The blood damage results revealed an acceptable level of blood damage in the proposed design. Therefore, it is shown that the used of shrouded impeller design can lead to good results in miniature blood pumps.
Author
Dr. Talha Irfan Khan
How to Cite
Talha Irfan Khan (Doctorate thesis). Minyatür bir kan pompasının tasarımı analizi ve geliştirilmesi, 2018, Koç University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Koç University
- Ekom-Eczacıbaşı'nın Rusya piyasasındaki pazarlama stratejileri(1995)
- Barok döneminde Balkanlar Osmanlı Avrupası'nda mimaride, dekorasyonda, himaye ve kültürel üretim modellerinde dönüşüm, 1718-1856(2006)
- Erteleme kısıtlı tek makine çizelgeleme(2014)
- Sarayda Osmanlı tütsüleme gelenekleri: Topkapı Sarayı buhurdanları(2015)
- Selçuk Rumları ve Gürcistan Krallığının Birbirlerine olan benzerlikleri: 13. Yüzyılda sanatsal değişim çerçevesi(2015)
- Obje tabanlı akıl danışma-tavsiye iletişimi tasarımına ilham kaynağı olarak Türk kahve falı(2017)