PDMS ince filmlerin viskoelastik karakterizasyonu
2018
0 views
0 downloads
Advisor: Doç. Dr. Burhanettin Erdem Alaca
Abstract (EN)
Despite the fact that a small uncertainty in the PDMS Poisson's ratio leads to significant errors in traction force microscopy, there is a clear lack of data for PDMS films at the scale of 100 μm, a relevant size scale frequently employed in cell mechanics studies. Equally important is the need for the consideration of the viscoelastic nature of PDMS, as no mechanical property–including the Poisson's ratio can be taken as a time-independent constant. The foremost challenge for addressing these issues is the difficulty of carrying out stress relaxation tests on miniature PDMS samples accompanied by non-contact strain measurement with a very high spatiotemporal resolution. This study introduces such a stress relaxation platform incorporating i) the proper means for the application of necessary boundary conditions, ii) a high-precision in load measurement, and iii) a non-contact, local strain measurement technique based on single particle tracking. During stretching, images are recorded at a rate of 18 Hz with a 40 μm spatial resolution. Microsphere-embedded PDMS films as thin as 125 and 155 μm are prepared to study the Poisson's ratio by a local strain microscope. After tracing the displacement of microspheres by a single particle tracking method and using a strain mapping, Poisson's ratio for 155-μm-thick PDMS is measured to decrease from 0.483±0.034 to 0.473±0.040 over a period of 20 mins. For 125-μm-thick PDMS, this reduction takes place from 0.482±0.041 to 0.468±0.038. Moreover, a non-monotonic reduction is observed in both cases. This negative correlation between Poisson's ratio and relaxation time is found to be statistically significant for both thicknesses with p<0.001. The viscoelastic behavior is further characterized through the Burgers model. With a measurement field of 597x550 μm2, this study emphasizes the importance of the local investigation of mechanical properties. Furthermore, the dependence of transverse strain on a film thickness difference of 30 μm is measured to determine the sensitivity of local strain tracking. The inherent high resolution of the proposed approach enables one to measure deformations more precisely and to observe the temporal evolution of the Poisson's ratio that has not been observed before. In addition to the high-precision determination of PDMS Poisson's ratio, this work also offers a promising pathway for the accurate and time-dependent determination of the mechanical properties of other soft materials, where similar ambiguities exist regarding the mechanical behavior. The technique can also be used to establish a link between the conditions PDMS is exposed to during cell growth process and its mechanical properties.
Author
Dr. Sedat Doğru
How to Cite
Sedat Doğru (Master Thesis). PDMS ince filmlerin viskoelastik karakterizasyonu, 2018, Koç University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Koç University
- Ekom-Eczacıbaşı'nın Rusya piyasasındaki pazarlama stratejileri(1995)
- Barok döneminde Balkanlar Osmanlı Avrupası'nda mimaride, dekorasyonda, himaye ve kültürel üretim modellerinde dönüşüm, 1718-1856(2006)
- Erteleme kısıtlı tek makine çizelgeleme(2014)
- Sarayda Osmanlı tütsüleme gelenekleri: Topkapı Sarayı buhurdanları(2015)
- Selçuk Rumları ve Gürcistan Krallığının Birbirlerine olan benzerlikleri: 13. Yüzyılda sanatsal değişim çerçevesi(2015)
- Obje tabanlı akıl danışma-tavsiye iletişimi tasarımına ilham kaynağı olarak Türk kahve falı(2017)
