Analysis of stress generated by implant-supported prostheses with pontic and cantilever designs on different abutment types in the posterior mandible using the finite element stress analysis method
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Aim: In implant-supported prostheses, which are commonly used in the treatment of tooth loss, variables such as the number of implants, their position, and the design of the superstructure directly affect the stress distribution within the system. In this study, different implant placements that can be applied in cases of three missing teeth in the posterior mandible, along with splinted, pontic, and cantilevered superstructure designs, were evaluated using the finite element stress analysis method with three different abutment types. Material and Method: In the study, 4.3 mm diameter and 10 mm length bone level Nobel Parallel™ Conical Connection implants were modeled according to catalog dimensions. The abutments have a gingival height of 2 mm and a total height of 5.5 mm. The cement layer between the superstructure and the abutment was modeled at 50 µm, and the teeth were created according to anatomical references. Splinted, pontic, and cantilevered superstructures were designed according to the implant placement, and all models were analyzed under vertical and oblique loads. Results: Stress distribution varied depending on abutment type, prosthesis design, and load direction. An increase in the number of implants reduced stress levels, and pontic designs exhibited lower stress compared to cantilever designs. Stress increased significantly, particularly in distal cantilever models. The highest stress under vertical load was observed in prefabricated abutments, while under oblique load it was seen in custom abutments. Ti-base abutments produced moderate stress in both load directions. Stress distribution was found to be more homogeneous in splinted models. Principal stresses in cortical bone were higher than in trabecular bone, but all values remained within physiological limits. Conclusion: The highest stress was observed in the distal cantilever + custom abutment combination under oblique force, and this configuration was determined to be the most biomechanically risky option. Keywords: Dental abutment, cantilever, pontic, FEA, posterior mandible
Author
Rumeysa Okur
How to Cite
Rumeysa Okur (Dentistry Specialty Thesis). Analysis of stress generated by implant-supported prostheses with pontic and cantilever designs on different abutment types in the posterior mandible using the finite element stress analysis method, 2025, Eskişehir Osmangazi University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Eskişehir Osmangazi University
- Investigation of the relationship between intolerance of uncertainty and attachment styles in patients diagnosed with generalized anxiety disorder(2024)
- The relationship between teachers' reading motivations and perceptions of critical reading self-efficiency(2023)
- Interaction with different chemical additives and corrosion inhibitors in concrete(2023)
- Investigation of joining parameters of alumina to Ti6Al4V ve AISI 316L stainless steel by active brazing method(2023)
- The effect of strategy package based on the self-regulated strategy development model on the narrative writing skill of students with specific learning disabilities(2023)
- The four elements: Earth, air, fire and water in Anatolian and Indian fairy tales(2023)