Comparison of color measurement methods in wastewater
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
The metallic salts dissolved in water color, or colloid particles in the water. According to some other color parameter waters polluting parameter special attention.Although many of the pollutant parameters can be measured and evaluated objectively, the color parameter has a little bit of subjectivity as well as objective properties. Since the color parameter is reflected by light reflecting the salts and colloidal substances in the water, the wavelengths which provide the colors to be formed are the most important parameters to be considered in the measurement of the colors. These wavelengths determine both the color variations and the selection of the measurement method. Since the color formation in the water consists of both the colloid substances in the water and the dissolved substances, the measurement is measured both globally and after the water samples are filtered separately to determine where the color formation originates. Color measurement in water is measured by Standard Method 2120 C and TSE EN ISO 7887 B Spectrophotometric method. In order to reach the correct result in color measurements, the wavelengths that give the correct result for certain colors should be selected. If the same wavelength is selected for all colors, most of the results will be incorrect. Platinum-Cobalt value and single wavelength measurement method are used in our country. In this measurement, it gives correct results in yellow and orange color tones at 456 Nm wavelength and it is misleading in other colors. Therefore, different methods have been developed. These method are used in different countries; -ADMI, -RES . According to this; -Platin-Cobalt, 456 Nm wavelength, yellow-orange colors, -ADMI, 720 Nm wavelength, yellow-orange colors, -RES, 436 Nm, 525 Nm and 620 Nm wavelength, Yellow, Red and Blue measurements were made. It is not correct to use Pt-Co for all colors in our country. In this study, different color measurement methods have been studied and compared with each other and what color and the correct method for which wavelength can be determined. It was emphasized that the regulations in our country would not be correct to give a standard for a single method for all colors.
Author
Meltem Pakize Polat
Institution
How to Cite
Meltem Pakize Polat (Master Thesis). Comparison of color measurement methods in wastewater, 2018, Hasan Kalyoncu University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Hasan Kalyoncu University
- The role of the demographic properties of the Erasmus program in the effect of cultural intelligence(2016)
- Termination of joint-stock companies and legal consequences of termination(2018)
- Multipurpose design and design of the building of the building of hotel: Gaziantep Teymur Continental Hotel example(2019)
- Research on the social adaptation of Iraqi refugees in Turkey(2019)
- Dış politika karar alma sürecinde inanç etkisi: Kudüs örneği(2019)
- Selection of suitable thermal method for disposal of domestic solid wastes in Balıkesir(2019)
