An investigation of compressive strength of concrete cylinder samples of different geometries on water/cement ratio and cement

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

2010
0 views
0 downloads

Abstract (EN)

In this study, effect of concrete cylinders having different diameters prepared by; cement factor (300-400-500 dosage), by water/cement ratio (0,3-0,4-0,5-0,6), by concrete aggregate (river sand, rock sand) on the compressive strength of concrete compressive strength was examined. On condition that h/d=2, concrete cylinder samples of 5x10cm, 7,5x15cm, 10x20cm, 12,5x25cm and 15x30cm were tested for compressive strength of 28th day. The compression strength results of different sizes of concrete cylinders were compared to compression strength results of standard concrete cylinders, as a result of the studies, it was concluded that the change in the height of cylinders had a significant effect on compression strength of samples.Key Words: Concrete, Compressive Strength, Size Effect, Cylinder Samples