Master'sOpen Access

The transit time based ultrasonic flow meter

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

2007
0 views
0 downloads

Abstract (EN)

In this study, the high frequency sound wave technology which is known as ultrasound and is becoming widely used in calorie-metric flow meters was experimented on the ordinary flow meters. The transit time method has been considered as the basis of the flow measure. Time to digital converter and the PIC18F4520 as a microcontroller were used to achieve a high accuracy time measurement in this study. In addition, two 4 MHz ultrasound transducers were used in the system. A diagonal type tube was used due to its simple construction. The effects that the flow meter is exposed to and the experimental results accuracy errors obtained from these effects are studied in the study. Science Code : 905.1.035 Key Words : Flow meter, ultrasound, measurement accuracy, calibration Page Number : 145 Adviser : Assist.Prof.Dr. İres İskender

Author

Emre Ertaş

How to Cite

Emre Ertaş (Master Thesis). The transit time based ultrasonic flow meter, 2007, Gazi University.

Keywords

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Gazi University