Investigation of the effect of conversion time and average number on performance in maximum power point tracking algorithms
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
In order to increase the efficiency of renewable energy systems, they need to be operated at maximum power point (MPP). This method, called Maximum Power Point Tracking (MPPT), consists of an electronic circuit and an algorithm that provides control. Switch and Observe (P&O) and Increased Conductance (INC) algorithms are the most widely used MPPT algorithms based on current and voltage measurements. In this study, the effects of averaging numbers and conversion times, which affect the measurement accuracy in classical MPPT algorithms, on the performance of the algorithms were investigated. A simulation study was conducted using thermoelectric generators and experimental studies were conducted using solar panels. It was observed that the ripple factor decreased as the averaging number and conversion time increased, but the times to reach the maximum point increased. While the averaging numbers and conversion times were increased in the P&O algorithm, a decrease in the minimum value of the power was observed, while an increase occurred in the INC algorithm. The minimum power for 64/128/256 averaging numbers in the P&O algorithm at a conversion time of 1.1 ms was measured as 8.3/8.0/7.7 W, respectively, while for the INC algorithm it was 7.5/7.75/7.8 W. The same situation was observed at a conversion time of 2,116 ms. The average power values were calculated in MPP for the P&O and INC algorithms. The average power was calculated greater for 128 averaging numbers in all conversion times for both algorithms. The average power for 64/128/256 averaging numbers in the P&O algorithm at a conversion time of 1.1 ms was calculated as 12.005/12.007/11.99 W, while for the INC algorithm it was 11.70/11.78/11.78 W.
Author
Salih Can Demiryürek
Institution

Tokat Gaziosmanpaşa University
Elektrik Elektronik Mühendisliği Bilim Dalı
How to Cite
Salih Can Demiryürek (Master Thesis). Investigation of the effect of conversion time and average number on performance in maximum power point tracking algorithms, 2024, Tokat Gaziosmanpaşa University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Tokat Gaziosmanpaşa University
- Investigation of the role of ARPC1A gene in the development of periodontitis(2022)
- Population in Karakus (Akkus) district (H. 1246-h. 1259)(2023)
- Muslim population in Turhal accident according to Population Registers (1831-1844)(2020)
- The Müslim population in the Kirchova districh according to population registers (1833-1846)(2024)
- Determination of the optimal value of the volume in the combustion cavity depending on the gunpowder right in the mouth of the barrel in internal ballistics and analysis of the pressure distributions in the mouth of the barrel and the changes in the bullet velocity with experimental studies(2025)
- The life and foundations of Gülbahar Hatun, II. Bayezid's mother(2020)