Energy optimization with different components in S520 model vertical coolers
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Today, energy consumption originating from cooling systems occupies an important place in total energy consumption througout the world. Energy costs have increased in recent years. Parallel to this, there is an increase in energy demand. However, the desired levels in energy supply could not be reached yet and, on the energy crisis in the European continent after the Russia - Ukraine war, This situation necessitates energy saving in the cooling sector as in every sector. Thus, It is a necessity to develop new cooling systems with high energy efficiency and minimum environmental damage. For this purpose, COP (Coefficient of Performance) values and daily energy consumption of cabinets produced in four different configurations were compared. These configurations were obtained by mounting two different compressors with fixed speed and variable capacity, respectively, on a cooler insulated with polyurethane (PU) foam materials, and then on an alternative cooler insulated with a vacuum insulation panel (VYP). As a result of the study, it was determined that the COP coefficient of a refrigeration system working with a variable capacity compressor and insulated with VYP was the highest and the daily energy consumption was the lowest. It was observed that the system with fixed speed compressor and PU insulation had the smallest COP value and the highest daily energy usage among these four configurations. Although the COP value of the system insulated with PU and with a variable capacity compressor is higher than the system with a VYP insulated and fixed speed compressor, it has been observed that the daily energy consumption is higher due to the higher operating rate. When the test results are evaluated, it has been determined that when choosing compressors, which are the heart of cooling systems, it is necessary to choose options with high compressor efficiency and that the use of VIP materials instead of PU foam insulation has very positive results in terms of reducing energy consumption. Keywords: Cooling systems, compressor, polyurethane foam, vacuum insulation, cooler performance, energy efficiency
Author
Ahmet Turan Sözeri
Institution
How to Cite
Ahmet Turan Sözeri (Master Thesis). Energy optimization with different components in S520 model vertical coolers, 2024, Eskişehir Osmangazi University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Eskişehir Osmangazi University
- Fixed ellipse and fixed Cassini oval theorems in G-metric space(2024)
- Investigation of the relationship between intolerance of uncertainty and attachment styles in patients diagnosed with generalized anxiety disorder(2024)
- Investigation of rare earth elements (REE) and trace elements in intrusive rocks via remote sensing (RS) and geografic information system (GIS) methods: A case study of Sivrihisar region(2025)
- The relationship between teachers' reading motivations and perceptions of critical reading self-efficiency(2023)
- Interaction with different chemical additives and corrosion inhibitors in concrete(2023)
- A new perforated armor plate design providing level 3 protection for armored vehicles(2023)