Exergoeconomic analysis of arc plasma gasification system with cooling column
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
The main objective of this thesis is to perform the exergoeconomic analysis of the double feed-arc plasma gasification system with cooling column. In this regard, exergoeconomic analysis studies have been carried out by using the data obtained from the test and performance experiments using 25 kg of organic waste each. For exergoeconomic analysis studies, the exergoeconomic factor (fexseco) was calculated by taking into account some parameters such as operating life, working time, operation and maintenance-repair factor, exergy destruction, unit cost of electricity and organic waste. In addition, parametric variation of fexseco was analyzed by changing these parameters. In the calculations performed; i) Exergy loss in the system was calculated to be 427.42 MJ in test experiment and 301.85 MJ in performance experiments, ii) The exergy efficiency of the system was determined to be 36.53% in the test experiment and 51.20% in the performance experiment, iii) Initial investment improvement factor was estimated to be 0.087, iv) Total cost flow brought to a value was found to be 11.33 Euro.h-1 in test experiment and 13,60 Euro.hr-1 in performance experiment, v) Cost of total exergy losses was 12.41 Euro.hr-1 in test experiment and 13.03 Euro.hr-1 in performance experiment, vi) The fexseco was calculated to be 0.48 in the test experiment and 0.51 in the performance experiment, vii) The recovery rate of the system was determined to be 6.3%. Consequently, increasing the operating life and working time in both experiments decreased the fexseco value. Increasing the operating and repair factor and reducing exergy losses increased the exergyeconomic value. In addition, increasing the unit cost of electricity and organic waste will increase the costs associated with exergy loss, thus reducing the fexseco.
Author
Gonca Koç
How to Cite
Gonca Koç (Master Thesis). Exergoeconomic analysis of arc plasma gasification system with cooling column, 2021, Recep Tayyip Erdoğan University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Recep Tayyip Erdoğan University
- To evaluate the incidence of postoperative pain, swelling, and alveolar osteitis following surgical extraction of mandibular impacted third molars by comparing the incidence of postoperative pain, swelling, and alveolar osteitis encountered after standard surgical extraction using post-extraction CGF or PRP(2025)
- Evaluation of the relationship between the inflammatory potential of diet and oral and periodontal health in pediatric patients(2025)
- Distribution of Aedes aegypti and Aedes albopictus in Turkey, determination of vector status and population genetics(2023)
- Investigation of relationship between housing prices and macroeconomic variables in Turkey(2025)
- The evaluation of Population Registers of Coastal Villages in Gonio and Batumi Number 1170(2013)
- Molar incisor hypomineralization among 9-year-old children in Rize: Prevalence, etiology and effects on life quality(2021)