In-vivo evaluation of potential optical changes in the peri-implant soft tissue caused by implant-supported fixed prostheses using titanium abutment infrastructure
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
The aim of this study is to evaluate, in vivo, the potential optical changes that may occur in the peri-implant soft tissue (PST) following implant applications. A total of 90 implants placed in the maxilla (anterior region = 39; premolar region = 51) of 46 patients (female = 26; male = 20) were included in the study. Titanium abutments and metal-supported porcelain restorations were used in the fabrication of the prostheses. Initial color measurements (L0*, a0*, b0*) were taken prior to implant surgery; the second color measurements (L1*, a1*, b1*) were taken with healing caps in place; the third color measurements (L2*, a2*, b2*) were taken upon delivery of the prostheses; and the fourth color measurements (L3*, a3*, b3*) were taken one month after permanent cementation, all performed with a colorimeter. The first-to-second measurement difference was calculated as (∆E00*)1, the first-to-third measurement as (∆E00*)2, and the first-to-fourth measurement as (∆E00*)3. Statistical analyses were conducted using Friedman and Wilcoxon tests with Bonferroni correction, and Mann-Whitney U test was applied for anterior PST and premolar PST comparisons. Significant differences were found in PST values. The L0* values (APST = 62.7; PPST = 63.2) were higher than the L1*, L2*, and L3* values. In the APST group, the a0* value (11.4) was lower than the a1*, a2*, and a3* values, while in the PPST group, the highest a* value was observed in a0* (13.3). The b0* values in both the APST and PPST groups were lower than the b1*, b2*, and b3* values. In the APST group, a2* and a3* values showed a significant increase compared to the a0* value (p<0.05), and the b3* value significantly increased compared to the b0* value (p<0.05). All ∆E00* values in the APST and PPST groups indicated a clinically 'incompatible' (∆E00*>1.8) color change. The ∆E00* values in the PPST group were higher than those in the APST group, with the greatest color change observed between the first and second measurements in the PPST group ((∆E00*)1 = 4.54). In implant-supported fixed prostheses using titanium abutments and metal-supported porcelain, the brightness of the peri-implant soft tissue color decreases across different treatment stages and outcomes, with a shift toward a more yellow hue.
Author
Merve Yılmaz Güngör
How to Cite
Merve Yılmaz Güngör (Dentistry Specialty Thesis). In-vivo evaluation of potential optical changes in the peri-implant soft tissue caused by implant-supported fixed prostheses using titanium abutment infrastructure, 2024, Karadeniz Technical University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Karadeniz Technical University
- Prevalence and associated factors of tobacco use, alcohol consumption, alcohol use disorder among individuals aged 20 and above living in trabzon province(2025)
- Traditional agricultural culture of Trabzon province in terms of folklore(2023)
- Trabzon güney çevre yolu güzergahı Darıca (Akçaabat) - Yalı mahallesi (Trabzon) arasının mühendislik jeolojisi / Investigation of the planned route of the southern highway between Darıca (Akçaabat) - Yalı mahallesi (Trabzon) in terms of engineering geolog(2001)
- Yaşlandırma Süresinin Zn-27Al-1Cu Alaşımının Yapı ve Mekanik Özelliklerine Etkisi(2016)
- Hydrogeology of Karabağ village (Kağızman-Kars) environment and evaluation of groundwater quality(2023)
- "Risâletü'r-Reml" registered in the National Library with 06 Hk 2725/2 (Transcription-analysis-intralingual translation-facsimile)(2024)
