Assessment of the new TLD dosimeters by luminescence technique

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

2009
0 views
0 downloads

Abstract (EN)

The kinetic parameters of a newly prepared tissue-equivalent, highly sensitive thermoluminescent detector, Li2B4O7:Cu,Ag,P of sintered pellets have been calculated. Thermoluminescence (TL) glow curves of Li2B4O7:Cu,Ag,P samples after ß-irradiation showed peaks at about 384 K and 446 K with a heating rate of 1 Ks-1. The kinetic parameters, namely activation energy (E) and frequency factor (s) associated with the main glow peak (446 K) of Li2B4O7:Cu,Ag,P have been determined using isothermal decay (ID) and peak shape (PS) methods. The activation energies obtained by ID and PS method are calculated to be 1.12 and 1.13 eV (mean), respectively. The frequency factors obtained by both methods are 7.61x1011 s-1 and 3.53x1011 s-1 (mean), respectively. Results obtained using both methods are compared and discussed.