Soil water content and electric resistivity relation
2019
0 views
0 downloads
Advisor: Dr. Öğr. Üyesi Osman Kara
Abstract (EN)
In this thesis, soil samples were taken from certain points in Canca Neighborhood, Alemdar Village, Sargınkaya Village and Tekke Village in the Central District of Gümüşhane and they were subjected to a series of laboratory experiments. In order to determine the soil properties of the samples, as well as the water content and electrical resistance measurements of each soil sample in the laboratory, sieve analysis, liquid limit and plastic limit tests were performed. In addition, by comparing the obtained water content values and electrical resistances; The relationship between these two parameters of the ground was tried to be revealed. In the analyzes performed using the data obtained from soil samples taken from all regions, the highest correlation coefficients between water content and electrical resistance were obtained by exponential functions. From the graphs of Alemdar region, R2 (correlation coefficient) values were found to vary between 0.2366-0.4271, and as a result of the evaluation, a weak-medium correlation was observed between the water content and electrical resistance in this region. For the Canca region, there is a high-to-very high correlation between water content and electrical resistance, with R2 values ranging from 0.6521 to 0.8377. R2 values obtained from the graphs of Sargınkaya region vary between 0.004-0.7417 and there is a very weak-high correlation between the two parameters. R2 values obtained from the graphs of the Tekke region ranged between 0.2849-0.7263, while a highly variable (weak-high correlation) correlation was obtained between them. When the relations according to the types of clays found in soils are evaluated, the correlation coefficients of Canca and Tekke soils containing kaolinite clay are weak-very high. On the other hand, the relationship in the Alemdar region with illite clay content is weak-medium. In the soil of Sargınkaya region which contains illit-smectite clay group, it varies from very weak to high level. As a result; with the evaluation of all the data obtained, it was concluded that the changes in the correlation coefficient between the water content and electrical resistance values of the soil samples for the four regions vary depending on the geological composition of the different soil samples taken from the regions.
Author
Dr. Merve Tüzen
How to Cite
Merve Tüzen (Master Thesis). Soil water content and electric resistivity relation, 2019, Gümüşhane University.
Keywords
License
CC BY 4.0
This work is shared under the specified license terms.
More theses from Gümüşhane University
- RÜZGAR ENERJİSİ SANTRALİ İÇİN YER SEÇİM ANALİZİ: GİRESUN İLİ ÖRNEĞİ(2026)
- The effect of psychosocial support services on trauma and stress-related mental disorders in disaster and emergency situations: the example of kahramanmaraş earthquakes(2025)
- Yenilenebilir Enerji Kullanımının Ekonomik ve Çevresel Sürdürülebilirlik Üzerindeki Etkileri: Panel Veri Analizi(2026)
- GÜMÜŞHANE DEVLET HASTANESİNDEKİ HEMŞİRELERİN AFET TEHDİDİ İÇİN PSİKOLOJİK HAZIRLIKLARININ BELİRLENMESİ(2026)
- Üniversite Öğrencilerine Yönelik Ağır Kış Durumlarına Karşı Dirençlilik Ölçeğinin Geliştirilmesi(2026)
- ERZURUM ŞEHİR HASTANESİNDE ÇALIŞAN TIBBİ SEKRETERLERİN İŞ DOYUMU VE İŞ DOYUM DÜZEYLERİNİ ETKİLEYEN FAKTÖRLER(2026)