Electrocatalytic determination of hydrazine using aromatic sulfonic acid dyes modified electrodes in flow injection analysis system
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
In this thesis, the modification of four aromatic sulphonic acid dyes such as calmagite (Clm) chromotropic acid (Cta), tropeolin (Trp) and pyrocatechol violet (Pcv) which have a good redox mediator property was performed on pencil graphite electrode (PGE) via electropolymerization and adsorption procedures. Then the electrocatalytic oxidation of hydrazine was investigated by both cyclic voltammetric and amperometric techniques at these prepared modified electrodes. According to cyclic voltammograms recorded in 0.1 M pH 9.0 phosphate solutions, while hydrazine broadly oxidized at a high potential about 600 mV, it sharply oxidized at more negative potentials such as 300 and 150 mV at Clm and Pcv modified electrodes, respectively. Flow injection (FI) amperometric determination of hydrazine was also carried out using Poly-Clm/PGE and Pcv/PGE photoelectrochemical flow cell developed for PGE. From FI amperometric studies, the linear calibration range/limit of detection values were found to be 0.1-100 µM (R2=0.9999)/0.038 µM and 0.25-500 µM (R2=0.9995)/0.08 µM hydrazine at Poly-Clm/PGE and Pcv/PGE, respectively. The applicability of the developed FI amperometric hydrazine sensor to water samples has been tested and the obtained result showed that hydrazine added to tap water and seawater samples can be determined with a recovery of 98-102%. In addition, interferences of some cations on the electrocatalytic oxidation of hydrazine were eliminated by adding of EDTA and ethylene glycol to the solution. As a result, an amperometric hydrazine sensor with high sensitivity, selectivity and accuracy has been developed using Poli-Clm/PGE and Pcv/PGE in FIA system for the first time.
Author
Selen Ayaz
How to Cite
Selen Ayaz (Master Thesis). Electrocatalytic determination of hydrazine using aromatic sulfonic acid dyes modified electrodes in flow injection analysis system, 2018, Çanakkale Onsekiz Mart University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Çanakkale Onsekiz Mart University
- Investigation the effects of eight weeks pilates and step-aerobics on sturctural, biomotorical and physiocological variables of sedantery women(2014)
- The Bulgarian Exarchate(1998)
- Determination of the amount of Chernobyl-derived Cs-137 transported through Dardanelles Strait(2012)
- Synthesis and characterization of imine polymers containing carbazole unit(2012)
- Numeri̇c analysi̇s of elasti̇c wave equati̇ons at si̇li̇ndi̇ri̇c coordi̇nates usi̇ng fi̇ni̇te di̇fference method(2014)
- Quantitative determination of paracetamol in drug forms at poly (P-aminobenzenesulfonic acid)-modified glassy carbon electrode(2014)