Construction of electrochemical biosensor in flow injection and preparation of modified pencil graphite electrodes using aromatic sulfonic acid dyes
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
In this thesis, modified pencil graphite electrodes (PGE) were prepared with calmagite (Clm), pyrocatechol violet (Pcv), tropeolin (Trp) and chromotropic acid (Cta) mediators which are aromatic sulphonic acid (ASA) dyes. Electrocatalytic oxidation of NADH ( reduced form of β- nicotine amide dinucleotide) was investigated with these prepared modified electrodes using cyclic voltammetry. Among the prepared modified electrodes, Trp and Cta modified PGEs did not a show good electrocatalytic activity. However, a good electrocatalytic result was obtained in the case of modified Clm/PGE and Pcv/PGE prepared by electropolymerization procedure. Amperometric sensor of NADH based on its electocatalytic oxidation at modified electrodes which give good result has been developed in flow injection analysis system (FIA) using photoelectrochemical flow cell which was constructed for PGE in the previous studies. In addition, glucose biosensor based on NAD+/NADH redox couple was constructed by immobilization of glucose dehydrogenase onto Poly-Pcv/PGE and FI amperometric glucose biosensor has been developed by integration of FIA with aromatic sulphonic acid dyes modifed electrode for the first time. The linear calibration range, LOD, and LOQ values of the modified electrode (GDH / Poly-Pcv/PGE) designed for the glucose biosensor were found to be 5-500 μM, (R2 = 0.9984), 1.2 μM and 4.0 μM glucose, respectively. The applicability of constucted biosensor was tested successfully by determination of glucose in dextrose solution which is commercially purchased. Moreover, the effect of interference of some substances on the constructed biosensor have also been performed. Both surface and electrochemical characterization of Clm and Pcv modified electrodes which give a good results toward electrocatalytic oxidaiton of NADH together bare PGE have been performed. For this purpose, AFM, SEM an EDX images and Raman and electrochemical impedance spectra of each electrode were recorded.
Author
Mehmet Güneş
How to Cite
Mehmet Güneş (Doctorate thesis). Construction of electrochemical biosensor in flow injection and preparation of modified pencil graphite electrodes using aromatic sulfonic acid dyes, 2018, Çanakkale Onsekiz Mart University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Çanakkale Onsekiz Mart University
- Investigation the effects of eight weeks pilates and step-aerobics on sturctural, biomotorical and physiocological variables of sedantery women(2014)
- The Bulgarian Exarchate(1998)
- Determination of the amount of Chernobyl-derived Cs-137 transported through Dardanelles Strait(2012)
- Synthesis and characterization of imine polymers containing carbazole unit(2012)
- Numeri̇c analysi̇s of elasti̇c wave equati̇ons at si̇li̇ndi̇ri̇c coordi̇nates usi̇ng fi̇ni̇te di̇fference method(2014)
- Quantitative determination of paracetamol in drug forms at poly (P-aminobenzenesulfonic acid)-modified glassy carbon electrode(2014)