Designing a chest pulse oximeter to measure blood oxygen level
Bu tez size mi ait?
Bu kayıt toplu arşivden geldi. Sizinse profilinize bağlayın.
Özet (EN)
Nowadays, the biomedical devices hold a prominent position within medicine. Pulse oximeter has become a significant tool to detect oxygen level in blood. This measurement can be performed from different sites of human body such as fingertip, forehead, earlobe and nose. However, medical doctors agree that any SpO2 measurement should be better performed from sites closer to the heart in order to detect some diseases in their early stages. In this study, a reflective sensor was designed and SpO2 estimations were carried out from right index fingertip and intercostal artery in center of left chest and then, the results were compared. In this device, the sensor capture red and infra-red light that comes from related area from human body and produces an analog signal. The captured signal was amplified, filtered, digitized and sent to Personal Computer to process by using several digital windows namely Hamming, Blackman, Bartlett, Digital Prolate Spheroidal Sequence, Kaiser and Parzen-Rosenblatt. SpO2 estimations were obtained from related calibration equation for each window output. These equations were obtained from measurements of eight healthy volunteers. Another group of twenty-one healthy volunteers are included into the study while obtaining SPO2 estimations from right index fingertip and from the intercostal artery in the center of the left chest. The average SpO2 estimated from chest photoplethysmograms are 95.87±0.26, 95.88±0.26, 95.93±0.64, 95.75±0.36, 95.84±0.32 and 95.78±0.28 for Digital Prolate Spheroidal Sequence, Hamming, Kaiser, Blackman, Bartlett and Parzen-Rosenblatt windows, respectively. The average SpO2 estimated from fingertip photoplethysmograms are 96.15±0.29, 96.15±0.25, 95.70±0.40, 96.07±0.35, 96.12±0.41 and 96.13±0.31 for DPSS, Hamming, Kaiser, Blackman, Bartlett and Parzen-Rosenblatt windows, respectively. The results show that, there is no systematic difference between SpO2 estimations from chest and fingertip (P<0.5).
Yazar
Surhan Bozkurt
Bu Yayına Nasıl Atıf Yapılır
Surhan Bozkurt (Master Thesis). Designing a chest pulse oximeter to measure blood oxygen level, 2015, Yeditepe University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Yeditepe University tezlerinden daha fazlası
- The effect of self-concept clarity on imposter phenomenon(2024)
- Enhancing Turkish traffic sign recognition: A comparison of training step numbers, lighting conditions and image sizes(2022)
- Whatever singularity: Queering the 'Quodlibet' in The Well of Loneliness and Oranges are not the Only Fruit(2022)
- Turkish reliability and validity of the nutrition screening tool for childhood cancer (SCAN)(2022)
- 1736-1739 Ottoman-Russo-Austro Wars and the Crimean Khanate(2023)
- Implanting false autobiographical memories and the effect of mood on false autobiographical memory creation(2023)