Master'sOpen Access

Testing for validation of measurement of energy consumption in exercises with four-sensor arm band device

2011
0 views
0 downloads
Advisor: Prof. Dr. Cem Şeref Bediz

Abstract (EN)

Purpose: The purpose of this study is to measure and compare energy consumption during exercise by SenseWear Armband and indirect calorimeter and test the validation of SWA.Method: An exercise consisting of four parts is practiced on total 21 individuals with 21,38 age average (±2,2) ; 10 male, 11 female. Recovery-energy consumption, maximal oxygen consumption of individuals have been measured and at a speed about 30% and 60% of measured value laboratory and site running have been done. SenseWear Armband has been placed on right triceps of participants and energy consumption has been calculated in accordance with the equalities produced specifically. Energy consumption has been measured with SenseWear Armband and Oxycon Mobile (an open-system, portable indirect calorimeter)Results: SenseWear Armband measured recovery-energy consumption 0,080 kcal/minute more than, 0,265 kcal/minute in 30% laboratory running, 1,20 kcal/minute in 60% laboratory running, 0,165 kcal/minute in 30% site running and 1,153 kcal/minute in 60% site running less than indirect calorimeter. Statistically there is not any important difference only in 30% site running (P=0,17). In recovery there is statistically important difference respectively in recovery (P=0,0005), 30% laboratory running (P=0,022), 60% laboratory running (P=0,003), 60% site running (P=0,0008). In spite of these differences, Powerful, very powerful and middle correlation has been found respectively in recovery between SenseWear Armband and Oxycon(r=0,837), 30% site running (r=0,725) and 30% laboratory running (r=0,877), 60% laboratory running(r=0,516) and 60% site running(r=0,511).Conclusion: : In accordance with the results of study, SenseWear Armband energy consumption has been measured generally less than Oxycon. Difference between them increases as long as energy strength increases. But considering the powerful correlation between results, it is quite possible to say that SenseWear Armband is a valid method in measuring recovery and exercise. Especially specific equalizations of SenseWear Armband can be developed in order to measure energy consumption during exercise.Keywords: Energy Consumption, Sense Wear Armband, Indirect Calorimeter, Physical Activity.

Author

Dr. Leman Kırıcı

How to Cite

Leman Kırıcı (Master Thesis). Testing for validation of measurement of energy consumption in exercises with four-sensor arm band device, 2011, Dokuz Eylül University.

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Dokuz Eylül University