Elektroeğirme ile hazırlanan nanofiber membranlara ürikaz immobilizasyonu ve voltametrik ürik asit biyosensörü olarak kullanımı
2022
0 görüntülenme
0 i̇ndirme
Danışman: Prof. Dr. Burhan Ateş ; Doç. Dr. Ahmet Ulu
Özet (EN)
Uric acid (UA) is clinically used as a marker of various diseases, especially gout and hyperuricemia. Therefore, precise measurement of biological samples such as serum and food samples is crucial. Uricase (urate oxidase, E.C.1.7.3.3, UOx) is the enzyme responsible for the oxidation of UA to allantoin in the body, and it is widely used especially in measuring UA level in vitro. In practice, there are colorimetric, chromatographic, spectrophotometric and biosensor-based methods for UA determination. However, a crucial need for determination of UA is exist, especially the creation of rapid results, selective and easy-to-use systems. In this study, the preparation of screen-printed electrodes containing membranes prepared by electrospinning, immobilization of UOx enzyme and its use as an voltammetric UA biosensor for the selective and sensitive determination of UA are available. In this context, polycaprolactone (PCL, 10%) was used in the membrane prepared by electrospinning due to its mechanical strength, and polyethyleneimine containing amine group (PEI, 7.5%) was used for the immobilization of the enzyme. Quantum Dot Screen Printed Electrode (QD - SPCE) containing two different membranes was prepared. One of them is PCL/PEI /UOx /QD – SPCE, the other is PCL/PEI/UOx/MB/QD–SPCE supplemented with methylene blue (MB). The prepared membranes were structurally characterized by FTIR, EDX and XRD, morphologically by SEM and voltammetric by water contact angle. Standardization in was performed by DPV (Differential Pulse Voltammetry) technique for UA concentration between 5 and 52 µM in PBS pH 7.4. Results were determined as LOD: 3.9619 ± 0.588 µM (R 2 = 0.9947) for UOx/QD–SPCE, while LOD: 1.8598 ± 0.2345 µM (R 2 = 0.9988) for UOx/MB/QD–SPCE. The 4-week stability results showed the change in current for UOx/QD–SPCE and UOx/MB/QD–SPCE to be 92% and 87%, respectively. In addition, in the mixed interference test remaining current ratios for UA were 95% and 82% for the UOx/QD–SPCE and UOx/MB/QD–SPCE electrodes, respectively. As a result, it has been determined that the two prepared biosensor systems have comparable measurement qualities with the sensors in the literature in UA measurement.
Yazar
Dr. Fakhrıy Muhammad
Bu Yayına Nasıl Atıf Yapılır
Fakhrıy Muhammad (Master Thesis). Elektroeğirme ile hazırlanan nanofiber membranlara ürikaz immobilizasyonu ve voltametrik ürik asit biyosensörü olarak kullanımı, 2022, İnönü University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
İnönü University tezlerinden daha fazlası
- Knowledge, opinions and applications of pediatric nurses towards therapeutic games(2017)
- The effects of systemic pistacia eurycarpa yalt administration on alveolar bone loss and oxidative stress in rats with experimental periodontitis(2021)
- The effect of motivational interviews for primiparous pregnant women with low normal birth belief on medical and natural birth belief(2022)
- Retrospective investigation of genetic etiology in pediatric epilepsy patients based on targeted next generation sequence analysis datas(2022)
- The commentary methodology in the commentary on al-Fath al-Mubyn bi-Sharh al-Arba'eyn by Ibn Hajar al-Haytamy(2022)
- Comparison of serum BDNF, S100B levels of patients with bipolar disorder in manic and remission periods with healthy volunteers and evaluation of results with neuropsychological tests(2022)