Tetracycline, oxytetracycline and chlortetracycline removal with fenton process
2021
0 views
0 downloads
Advisor: Dr. Öğr. Üyesi Engin Gürtekin
Abstract (EN)
Antibiotics are among the pHarmaceutical groups used for many therapeutic chemicals in humans and animals. In parallel with the rapidly increasing world population in recent years, drug use has also increased. Antibiotics are an important micro-pollutant group found in wastewater and receiving environments due to their very common use. The presence of such micro-pollutants in the aquatic environment and threatening the environment made it compulsory for the scientific world to conduct research in this direction. In this study, Tetracycline, Oxytetracycline and Chlortetracycline removal from the aquatic environment was investigated by fenton process. For this purpose, the optimum operating parameters of pH, Fe+2 and hydrogen peroxide (H2O2) concentrations, reaction and precipitation times, which are also effective in the fenton process for pollutant removal, have been determined. During the working period; pollutant (TC, OTC, CTC 100 ppm), pH (2-3-4), Fe+2 (0-20-40 mg / L), H2O2 (25-50-100 mg / L), reaction time (2-5 -10 min) and precipitation time (15-30-60-90 min) conditions were tried. Optimum conditions in TC removal trials; pH: 4, Fe+2: 30 ppm, H2O2: 100 ppm, reaction time: 10 minutes and 90 minutes for precipitation time. Under these optimum conditions, 100% TC removal was achieved. For OTC removal; pH: 3, Fe+2: 20 ppm, H2O2: 25 ppm, reaction time 5 minutes and waiting time 90 minutes for precipitation. Under these conditions, 100% OTC removal was found. For CTC removal; pH: 3, Fe+2: 20 ppm, H2O2: 25 ppm, reaction time: 5 min and waiting time for precipitation were observed as 90 min. Under these optimum conditions, CTC removal efficiency was found to be 99.68%. As a result of this study, it was found that fenton process is an effective method for TC, OTC and CTC removal.
Author
Murat Çelik
Institution
How to Cite
Murat Çelik (Master Thesis). Tetracycline, oxytetracycline and chlortetracycline removal with fenton process, 2021, Fırat University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Fırat University
- Using social media as an integrated marketing communication tool(2018)
- Foundation of Dutch East İndia Company and her rising in İndonesia in the 17th century(2013)
- Examination of stress state between Doğanyol (Malatya) and Çelikhan (Adıyaman) on the east Anatolian fault zone(2020)
- Color usage at Turkish Divan of Fuzûlî(2013)
- Yavuzeli (Gaziantep) surrounding volcanic outcropping of rocks petrographic and geochemical features(2014)
- Hizbu?t-Tahrir and the religions and political thoughts of Ercumend Özkan(2008)