Abstract (EN)
In this thesis, the biocompatibility of Ni-Ti (Nitinol) alloy coated with hydroxyapatite (HA) was investigated. Many thin film coating methods have been developed in order to be able to do thin film coating with ceramic materials. In this study, RF Sputtering and Sol gel methods (dipping and spin coating) were used. It is aimed to increase the biocompatibility of the Ni-Ti alloy with the HA coatings. In the coatings performed with the RF Sputtering method the thicknesses were determined with respect to the coating time and 3, 6 and 9 hours coatings were done for three different samples. Four different coatings at different thicknesses were done with Sol gel dipping method. The coating thickness was proportional to the number of dipping and after each coating process, to dry the samples a heat treatment for 1 hour at 100 oC were done. Subsequently, the samples were sintered for 1 hour at 500 oC. In the spin coating methods, the coating thicknesses were determined according to the number of revolutions per second and two different rotation speeds, which are 300 and 1350 rpm, were used. The coated samples were heat treated at 100 oC for 1 hour and then at 500 oC for 1 hour. The HA solution used for the coating was prepared using calcium nitrate tetrahydrate (Ca(NO3)2.4H2O) and ammonium dihydrogen phosphate (NH4H2PO4) precursors. The optimum conditions (martensite-austenite phase transformation temperature) where the Ni-Ti alloy exhibits shape memory effect were determined by DSC measurements.The morphological properties of the coating surfaces were investigated by SEM-EDX analysis, and the crystallographic structure of HA was determined by XRD and FTIR analysis. In the dip coating method, it has been observed that the cracks form on the surface as the coating thickness increases and it will have a negative effect on biocompatibility because of the release of harmful Ni ions to the body from these cracks. However, these surface deformations were not observed in the coatings done by spin coating method, and more homogeneous coatings were obtained compared to the dipping method.
Author
Dr. Gökhan Kesin
How to Cite
Gökhan Kesin (Master Thesis). Hydroxyapatite coated orthodontic shape memory Ni-Ti alloys and biocompatibility, 2022, İnönü University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from İnönü University
- Knowledge, opinions and applications of pediatric nurses towards therapeutic games(2017)
- The effects of systemic pistacia eurycarpa yalt administration on alveolar bone loss and oxidative stress in rats with experimental periodontitis(2021)
- The effect of motivational interviews for primiparous pregnant women with low normal birth belief on medical and natural birth belief(2022)
- Retrospective investigation of genetic etiology in pediatric epilepsy patients based on targeted next generation sequence analysis datas(2022)
- The commentary methodology in the commentary on al-Fath al-Mubyn bi-Sharh al-Arba'eyn by Ibn Hajar al-Haytamy(2022)
- Comparison of serum BDNF, S100B levels of patients with bipolar disorder in manic and remission periods with healthy volunteers and evaluation of results with neuropsychological tests(2022)