Design and development of new generation electrodes for use in in vitro diagnostic systems

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

Abstract (EN)

This study aims to fabricate electrodes with properties of both gold and diamond-like carbon (DLC) thin films for in vitro diagnostic system applications for the first time. A specific self-assembly method was used to prepare conductive gold nanonetwork bonded diamond-like carbon nanofilm (CGN-DLC) electrodes with multifunctional surface and bulk properties. The nanofilms possessed a relatively high sp3 carbon fraction, a high electrical conductivity (1,4 × 103 S.cm-1) and optical band gaps of 1,42 eV and 3,87 eV. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS) revealed the presence of carboxylic acid functional groups on the DLC surface. High-resolution transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), RAMAN spectroscopy, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EİS) were used to help qualitative and quantitative assessing of CGN-DLC nanofilms. TEM and SEM analyzes demonstrated the successful use of trisodium citrate and gold nanoparticles to produce CGN-DLC nanofilms. The XRD spectrum indicated the Au (111), Au (200), Au (220) and Au (311) peaks of the gold nanonetwork and the C (002), C (032) and C (111) peaks of the DLC structure. The RAMAN spectroscopy demonstrated the D and G band peaks of the diamond-like carbon structure at 1388.6 cm-1 and 1568.0 cm-1, respectively. The sp3 content of DLC film was found approximately 30 %, as well. CV and EİS demonstrated that CGN-DLC nanofilms can be used as effective electrodes in biosensor applications. In the presented thesis, a sustainable method is shown for obtaining CGN-DLC nanofilms without using harmful chemicals or physical methods. To evaluate the performance of CGN-DLC nanofilm, it was coated on a pencil graphite electrode (PGE) and used in an electrochemical biosensor for the sensitive detection of miR-NA-410-5p as a prostate cancer biomarker. No amplifica-tion and/or labeling process was used on this biosensor platform. The prepared biosensor platform was detected target miRNAs using differential pulse voltammetry (DPV) method with a linear range of 0.3 fM to 100 fM and a detection limit (LOD) of 0.27 fM. As such, the CGN-DLC nanofilm is expected to find wide application areas such as bio/sensors, photovoltaics, transistors, amplifiers, energy storage elements and biomedical.

Author

Soheıl Malekghasemı

How to Cite

Soheıl Malekghasemı (Doctorate thesis). Design and development of new generation electrodes for use in in vitro diagnostic systems, 2021, Hacettepe University.

Keywords

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Hacettepe University