Design of wear tester for hip prostheses
2019
0 views
0 downloads
Advisor: Dr. Öğr. Üyesi Erkan Bahçe
Abstract (EN)
Total hip arthroplasty is a surgical procedure used to correct joint function in degenerative disorders of the hip joint. In the hip prostheses, clinical successes and developing technology together with the life of hip prostheses vary between 15 and 20 years. Depending on the increasing average life expectancy, total hip prostheses require longer usage times. According to these demands, hip prostheses which can be used during 30 to 40 years are needed. The life expectancy of hip prosthesis varies depending on the patient's personal characteristics with prosthetic materials and design. The concrete models of the studies, taking into account these factors for the increase in life span and the development of prosthesis, are subjected to pre-clinical testing at the stage of reaching the patient. For pre-clinical testing, hip simulators are used instead of animal subjects. The aim of this study is to design and manufacture the hip simulator according to the standards in order to determine the wear-life relationships of the manufactured and used hip prostheses. In the test device designed to have four degrees of freedom, spring systems were used to provide muscle and ligament effect in the hip joint simulation. After the production of parts designed with machining lathes, the assembly process was performed and three engines were programmed to move in harmony with each other. The first tests were carried out in one million cycles with a view to a wear value of 250,000 cycles. When the values obtained in the ISO 14242 standard were compared, a deviation of 1.18% was observed. The reason for this was the loss of efficiency in the engine performance characteristics. In addition, in the microscope images and mass loss values of the samples tested, the number of cycles increased and the wear rate and surface defects increased.
Author
Dr. Derya Karaman
How to Cite
Derya Karaman (Master Thesis). Design of wear tester for hip prostheses, 2019, İnönü University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from İnönü University
- Knowledge, opinions and applications of pediatric nurses towards therapeutic games(2017)
- The effects of systemic pistacia eurycarpa yalt administration on alveolar bone loss and oxidative stress in rats with experimental periodontitis(2021)
- The effect of motivational interviews for primiparous pregnant women with low normal birth belief on medical and natural birth belief(2022)
- Retrospective investigation of genetic etiology in pediatric epilepsy patients based on targeted next generation sequence analysis datas(2022)
- The commentary methodology in the commentary on al-Fath al-Mubyn bi-Sharh al-Arba'eyn by Ibn Hajar al-Haytamy(2022)
- Comparison of serum BDNF, S100B levels of patients with bipolar disorder in manic and remission periods with healthy volunteers and evaluation of results with neuropsychological tests(2022)