Master'sOpen Access

Milking hygiene and milk quality in a cooperative milking system

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

2016
0 views
0 downloads

Abstract (EN)

Dairy farmers who are doing business as a family base can not achieve the desired level of quality milk because of unhealthy conditions in milking. This is why the common milking unit is raised instead of a individial family dairy milking unit. In this study, our main objective is to determine the quality of milk in the milking unit in the cooperative milking system which is placed in Tastepe village. This investigation covers 34 dairy breeding farmers, who are doing business as a family base and their 137 holstein dairy cows which are using the cooperative milking system. This common usage milking system is organized by appointment, working hours starting in the morning at 5am to 7am and in the evening at 4pm to 5pm. Milk samples are taken both from indivudial dairy and from cooling milk tanks in order to determine the quality of milk in the time period once in June and August and also twice in September. Also it was discussed with 11dairy farmers who are using this cooperative milking system. All these 11 dairy farmers who graduated from primary school are confirming that they are spending an average 3,5 hours in a day for dairy breeding. The somatic cell count in the individual dairy cow samples of 17,1% is over 500.000 pcs./ml, 9,2% of these samples are over 1.000.000 pcs./ml. , total bacteria is over than 100.000 pcs./ml. in the 16,4% of the individual samples; 85,5% of samples defined Staphylococcus aureus and 22,4% of samples were found to be contaminated with different Streptococcus species. Somatic cell counts 500.000 pcs./ml. in samples from cooling tank, total bacteria is over than 100.000 pcs./ml. in 50% of samples. Total Staphylococcus aureus, in 71,7% of samples are higher than 500 pcs/ml. The same ratio for total Staphylococcus spp is specified 8,5%. In samples taken from the cooling tank; Somatic cell counts are under 500.000 pcs/ml., total bacteria is over 100.000 pcs/ml of 50% samples. Total Staphylococcus aureus and Streptococcus spp. 75% of cooling tank samples are over 500 pcs/ml. Somatic cell counts seems normal in samples of cooling tank but total bacteria counts are higher than the indivudial cow samples when compared to the cooling tank samples. Streptococcus spp. counts are higher than the indivudial cow samples when compare to the cooling tank samples. This situation proves there is contaminaton in the cooperative milking system. Keywords: Somatic Cell Counts, Total Bacteria, Staphylococcus aureus, Streptococcus spp.

Author

Umut Özkan

How to Cite

Umut Özkan (Master Thesis). Milking hygiene and milk quality in a cooperative milking system, 2016, Çanakkale Onsekiz Mart University.

Keywords

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Çanakkale Onsekiz Mart University