The evaluation of validity a portable clinical analyzer for the determination of blood ionized calcium concentration in cattle

2018
0 views
0 downloads
Advisor: Prof. Dr. Tolga Karapınar

Abstract (EN)

Information on reliability of the i-STAT, a point-of-care (POC) device, to determine blood ionized calcium (iCa2+) concentration is limited. Rapid determination of blood iCa2+ concentration can help evaluation of calcium status and delivery of effective therapy in field conditions. The goal of this study was to evaluate reliability of the i-STAT (Abbott Point of Care, Abbott Laboratories, Chicago, IL) in measuring blood iCa2+ concentration in cattle. In this prospective study 121 cattle with various diseases were used. Venous blood samples were run the i-STAT and the Radiometer ABL 800 (Radiometer, Copenhagen, Denmark) analyzer for determination of blood iCa2+ concentration. Data were subjected to paired Student t-test, concordance analysis, Passing-Bablok regression and Bland-Altman plots for comparison, accuracy, agreement and reliability. The Radiometer ABL 800 was reference method however the i-STAT was the test method. The i-STAT performance was also evaluated at two different cut-off values for blood iCa2+ concentration (< 1 mmol/L; <1.18 mmol/L) using the receiver operating characteristics (ROC) curve. The mean blood iCa2+ concentration measured by the i-STAT was similar to the mean blood iCa2+ concentration measured by the Radiometer ABL 800 (1.09 versus 1.09 mmol/L; P = .82). The i-STAT results were highly correlated with the Radiometer ABL 800 results (r= 0.98, P < .0001). Regression equation fitting blood iCa2+ concentration measured by the i-STAT (Y) and blood iCa2+ concentration measured by the Radiometer ABL 800 (X), was Y= -0.108276+1.103448× X, with a residual deviation (RSD) of 0.02. The deviation from the identity line was not significant (P = .64). The Bland-Altman difference plot revealed that the mean bias was zero. The i-STAT had Se of 100 % (95% CI, 87,7 - 100,0) and Se of % 94.8 (95 % CI, 87.2-98.6) at the cut-off blood iCa2+ concentration < 1 and < 1.18 mmol/L, respectively. The i-STAT yielded precise and accurate blood iCa2+ results in cattle. The i-STAT especially predicted hypocalcemia with high sensitivity. Key Words: calcium, dairy cow, point-of-care (POC), sensitivity.

Author

Öznur Yılmaz

How to Cite

Öznur Yılmaz (Master Thesis). The evaluation of validity a portable clinical analyzer for the determination of blood ionized calcium concentration in cattle, 2018, Fırat University.

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Fırat University