Photoneutron measurement and shielding in radiotheraphy
2016
1 görüntülenme
1 i̇ndirme
Danışman: Yrd. Doç. Dr. Yiğit Çeçen
Özet (EN)
Objective: In radiation therapy of cancer patients, high energy X-rays are used which are produced by linear accelerators. If the energy of these beams are over 8 MeV, they interact with metallic parts of the linear acceleator. This incident is called photonuclear reaction, as a result of these interactions, neutrons are also produced as secondary radiation products (γ,n). These neutrons are called photoneutrons. To prevent radiation damage from photoneutrons of the workers and the environment, the photoneutron flux and dose must be determined. The purpose of this study, the detection of photoneutron neutron flux consisting in the linear accelerators room and the determination of appropriate shielding materials and the development for this flux. Method: Photoneutron flux detection and testing of the neutron shielding neutron activation analysis method is used. Measurements made at different positions in the Philips SLI-25 linear accelerator treatment room and location-based distribution of thermal neutron flux are obtained. Measurements taken with AMATEM-ORTEC brand GMX-20195-P model n-type high purity germanium (HPGe) detector and GF3 spectrum analyzer program was used. Results: Maximum thermal neutron flux in the treatment room was found in the direction of G on the top of the linac head. Neutron flux 92% decrease to the walls, just in front of the linac door maximum neutron flux less than 1%. The shielding percentage of same neutron flux of the neutron shielding material; 5% boron doped polyethylene 89-90%, 10% boron doped paraffin 86%, high density polyethylene 64%, paraffin 62%, polyethylene 59%, polypropylene 58%, cast polyamide 53%. Conclusion: Linear accelerators photoneutron flux in the room, may lead the way for additional studies of neutron dose to the patient. Produced a 10% boron doped paraffin with the development of more effective and less costly shielding material can be manufactured neutron shield.
Yazar
Dr. Tuğçe Gülümser
Bu Yayına Nasıl Atıf Yapılır
Tuğçe Gülümser (Master Thesis). Photoneutron measurement and shielding in radiotheraphy, 2016, Akdeniz University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Akdeniz University tezlerinden daha fazlası
- Numerical investigation of the notch effect in interference fit connections(2023)
- Proje tabanlı öğrenimin İngilizce hazırlık sınıfı öğrencilerinin konuşma yeterlilikleri ve iletişim kurma istekleri üzerine etkisi(2025)
- The purpose of present study was to determine the levels of situational anxiety caused by the pressure of the competitive situations exposed to by child athletes and to objectively evaluate the parameters of Heart Rate Variability (HRV) and state anxiety accompanying the change in emotional state.(2022)
- The formation of Medieval Islamic economic thought within the scope of East-West interaction(2024)
- A cost comparison of rubble mound breakwater with breakwater covered by antifer block(2018)
- Enderunlu Fazıl – Hûbân-nâme (Edition critique)(2024)