Determination of acid mine drainage potential of a coal waste disposal site by static and kinetic test methods
2023
0 views
0 downloads
Advisor: Prof. Dr. Cengiz Karagüzel
Abstract (EN)
In this study, the environmental effects of the shale of a private colliery washing plant were investigated in the case of acid mine drainage (AMD). For this purpose, sampling and sample reduction processes and static (Sobek, ABA, ASTM) and kinetic (column, moisture cell) tests in international standards were applied. In the tests, the effects of working parameters such as grain size, column diameter, bacteria amount (thiobacillus ferrooxidans) on AMD were systematically investigated. While the static tests were evaluated according to the sulfur (%S) analysis of the solid samples, the kinetic tests were evaluated by looking at the pH, Eh (Electrical potential (mV)) and Ec(conductivity(mS/cm)) values and anion-cation and ion contents of the obtained filtrates. According to static tests, the total S value of the samples is in the range of 0.2-2.1% on average. While the average AUP value of the samples was 30.42544 kg*CaCO3/t, the average NP value was 182.6389 kg*CaCO3/t. The average NP/LUP is 8.88 kg*CaCO3/t. In addition, in the colon tests, the pH value was between 7.21-9.8, the Eh value was between 140-400 mV, and the conductivity was between 0.1908-30 mS/cm, excluding the experiments using bacteria. However, in experiments using bacteria, it was observed that the pH value changed. The Eh value was determined between 172-525 mV and the conductivity was determined in the range of 0.273-12 mS/cm. As a result, it was determined that the formation of acid mine drainage would not be expected in the area subject to the study. This is especially due to the high neutralization potential of the host rock. However, the increase in coal content in the schists as a result of inefficient operation in the ore enrichment plant will affect the current situation. Achieving sustainability depends on the high efficiency and performance of the facility. Kewords: Acid Mine Drenage, Anion-cation, Kinetic experiments, pH-Eh-conductivity, Static experiments
Author
Rasim Bayır
Institution
How to Cite
Rasim Bayır (Master Thesis). Determination of acid mine drainage potential of a coal waste disposal site by static and kinetic test methods, 2023, Kütahya Dumlupınar University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Kütahya Dumlupınar University
- Comparision of the leg and ARM CYCLE ergometer exercises in terms of the effects on physical and psychological functions in patients with undergoing coronary arter bypass surgery(2016)
- The production and characterization of zirconia-zirconium diboride (ZrO2-ZrB2) composites for structural applications(2016)
- The reflections of government grants on renewable energy sector in Turkey(2016)
- The analysis of regulation and supervision agencies' budget structures in Turkey: Banking Regulation and Supervision Agency sample (2005 - 2014 Period)(2016)
- Choised based conjoint analysis and an application(2016)
- Development of sepiolite doped materials in cement mortar adhesive(2016)