Technoeconomic analysis of the applicability of trigeneration systems in data centers
2021
0 views
0 downloads
Advisor: Doç. Dr. Mustafa Zeki Yılmazoğlu
Abstract (EN)
Parallel to the rapid development in information processing technologies, the need for data centers for data processing and storage is increasing day by day. Data centers have become more energy-dense than many building types in terms of energy consumption, especially due to the intense use in cloud systems and communication networks, especially during the crypto money and pandemic period. Energy costs have also had a significant share in the operation of these systems. Cooling the white area is important so that the internal temperature of the servers does not exceed the limit temperature in the electronic components. Starting from the design stage in data centers, the standard (Tier III, Tier IV, etc.) has been determined in the structure, such as the redundant design of the mechanical systems due to the 24/7 working requirement, modeling of air distribution with CFD analysis, and the creation of operating scenarios. In this study, by taking the energy consumption data of a data center in use, both electricity production and chilled water production were examined with the trigeneration option instead of the existing gaseous cooling system. Trigeneration systems will have very short payback periods in data centers mainly due to the requirement to be operated at full load continuously and the ability to produce chilled water by utilizing the waste heat of the main drive. According to the load profile obtained with the study, three different capacities of internal combustion engines were selected and the economic analysis of 20 years and the effect of the system on carbon dioxide emissions were discussed. According to the results, it has been determined that the system selection suitable for the data center capacity must be obtained through detailed analysis. The payback period of the system is calculated as 2-2,5 years. In addition, the average reduction in annual CO2 emissions has been calculated as 12 400-16 330 tons.
Author
Dr. Rıdvan Hatiboğlu
How to Cite
Rıdvan Hatiboğlu (Master Thesis). Technoeconomic analysis of the applicability of trigeneration systems in data centers, 2021, Gazi University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Gazi University
- Consumption preferences of university students: Ankara Haci Bayram Veli University and Çankaya University examples(2021)
- Theoretical investigation of the structural, electonic, elastic, phonon, thermodynamic and optical properties of XIn2O4 (X=Mg, Zn, Cd) compounds(2021)
- The fabrication of Au(MgO-PVP)/n-Si (MPS) Schottky barrier diodes and the investigation their electrical and dielectrical properties(2021)
- Development of boron containing electrolyte additive for lithium ion batteries(2021)
- Experimental development of the interfacial bond-slip model between textile reinforced mortar strips and masonry walls(2025)
- The effect of coaching support on preschool teacher's pre-literacy practices and pre-literacy skills of children(2021)