Evaluation of the effects of a newly developed laser system (ER,CR:YSGG) on fissure sealants applied on primary teeth in vitro
2008
0 görüntülenme
0 i̇ndirme
Danışman: Prof. Dr. Nurhan Öztaş
Özet (EN)
The aim of this in vitro study was to evaluate the marginal integrity (microleakage and marginal gap) properties and microtensile values of fissure sealants applied to Er,Cr:YSGG laser etched primary teeth by comparing with conventional acid etching techniqueExtracted sound primary molar teeth were randomly assigned to one of five study groups including (1) 37% orthophosphoric acid, (2) 2.5 W laser, (3) 3.5 W laser, (4) 2.5 W laser + 37% orthophosphoric acid and (5) 3.5W laser + 37% orthophosphoric acid. For the evaluation of marginal integrity, a conventional sealant material (ClinPro Sealant) was applied to the fissures whereas the same material was applied to the buccal surfaces of primary molar teeth for microtensile testing. Prior to marginal integrity evaluation, sample teeth were subjected to thermocycling and then immersed to 0.5% basic fuchsin solution for 24 hours. After sectioning, 3 slices of each sample teeth were scored under stereomicroscope in terms of microleakage and marginal gap. For microtensile testing, mean bond strength values of the sectioned teeth were calculated and failure types were evaluated under stereomicroscope in additon to taking representative micrographs with scanning electron microscope (SEMWith respect to microleakage, a statistically significant difference was found between acid group and 2.5 W and 3.5 W groups (p<0.05), whereas no significant difference was detected between acid group and 2.5 W + acid and 3.5 W + acid groups (p>0.05). In terms of marginal gap formation, no significant difference was observed between groups (p>0.05). The results of microtensile testing revealed that acid group was significantly different than 2.5 W group (p<0.05) and no significant difference was found between acid and the other study groups (p>0.05). 2.5 W group was found significantly different than all study groups (p<0.05). No significant difference was detected between 3.5 W, 2.5 W + acid and 3.5 W + acid groups (p>0.05).In conclusion, etching with the combination of Er,Cr:YSGG laser system with acid was found as effective as conventional acid etching. Although 3,5 W Er,Cr:YSGG laser etching was not found as successful as acid etching in terms of microleakage, it may be used for enamel etching considering that no difference was observed with acid with respect to marginal gap formation and microtensile bond strength values.
Yazar
Elif Sungurtekin
Bu Yayına Nasıl Atıf Yapılır
Elif Sungurtekin (Doctorate thesis). Evaluation of the effects of a newly developed laser system (ER,CR:YSGG) on fissure sealants applied on primary teeth in vitro, 2008, Gazi University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Gazi University tezlerinden daha fazlası
- Occupational accident analysis and modelling in oil and gas drilling sector Turkey(2021)
- XVI. yüzyıl Anadolu'sunda Oğuzların Karkın Boyu(2004)
- Sharing of real life geometry samples via a social learning environment: A case study(2021)
- Evaluatıon of calcium hydroxide removal efficiency of two different irrigation activation techniques from artificial internal resorption cavities prepared at different root levels(2021)
- Experimental development of the interfacial bond-slip model between textile reinforced mortar strips and masonry walls(2025)
- The use of verbal memory in the context of sustainability and power at the museums of Turk(2010)