Seismic design for port structures and example of Derince Port
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
The East Marmara Earthquake which occured centrally in Gölcük in 17th August 1999 (magnitude 7.4) caused lots of fatalities and structural damages that impacts social life and national economy. In this research, first of all berthing structures' design criterias are summerized, seismic design criterias and damage in Derince Port are dealed with. So the reason of damages in this port is tried to find. Damages are taken into consideration with structures' general layer plan and geotechnical conditions. In addition îzmit Bay's geological and hydrodynamic formatin is explained. Derin Port block type berthing structures were designed before 1997 earthquake specifications and site coefficients were taken smaller than the East Marmara Earthquake ground acceleration into calculations. This situations caused smaller factor of safetys. In that case, soil conditions and type of structure with design criterias had effected the seismic performance. Also taken into consideration port structure damages of the East Marmara Earthquake as summerized, the structures that will be planned and constructed in the future should be projected with the coefficients in 1997 earthquake specifications. Gravity type quay walls usually exhibited horizontal displacements towards the sea instead of backfill material quality and liquefaction. In addition this type of structures designed as taken smaller earthquake coefficients cause smaller factor of safety against sliding. This research's aim is to take lessons from EME disaster that is sorrowful for our country. Thus, to constitute basis for the designs that will be prepared against earthquakes in the future and be able to deal with them by minimum hazard. Keywords: Seismic design, port structures, block type quay walls, Derince Port
Author
Emre Tonguç
Institution
How to Cite
Emre Tonguç (Master Thesis). Seismic design for port structures and example of Derince Port, 2001, Yıldız Technical University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Yıldız Technical University
- A ruled-based software model in the preliminary design phase of housing: Example of Mardin(2008)
- 19th-20th centuries apartment buildings in Şişli and Osmanbey(2001)
- An investigation on the relationship between problem solving and critical thinking skill, and academic achievement of vocational and technical high school students(2017)
- Numerical investigation of single bubble flow boiling both on a flat surface and on a cavity in horizontal pipe and pool boiling on a flat surface(2018)
- Examination of the categories in which buildings with LEED v3 and v4 certificates score the lowest points in Turkey(2018)
- Examining ?Historical housing structures" within the confines of protecting ecological balance(2012)
