Bi-rads category 3 breast lesions on MRİ; follow-up results
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Our aim is to determine the frequency of BI-RADS category 3 lesions detected on MRG and analyze the malignancy rate in these lesions diagnosed under our criteria. Also to present MRI findings and to evaluate the patient compliance to our short-term follow-up protocol are our secondary purposes. We conducted this study retrospectively and after the permission of our ethic committee (Number: 70904504/115, Board Code: 2012-KAEK-20 / Date: 12.03.2018). From our PACS and hospital information systems (MEDI-HASTA 16.43 1997-2014, MIA-MED 1.0.1.3181 2014-2016, Siemens Leonardo Workstation 2009, SECTRA PACS IDS7 18.2.14.4021 2016), we found 913 patients undergone dynamic breast MRI between June 2014 and February 2018. Of these, 187 women had BI-RADS category 3 assessment. We excluded the patients who are not completing or participating to our follow-up protocol and whose biopsy results are not available. Finally 69 patients with 132 category 3 lesions, whose follow-up results and/or annual reports are available, composed our study group. We evaluated MRI findings comparing by mammography and US findings in these patients. Our short-term follow-up protocol on MRI is composed of three examinations at 6-month intervals for first year, and final examination at 24thmonth. Besides, we recommend age –appropriate screenings for the patients whose lesion is stabile after two years. If the category 3 lesions on MRI is seen also on mammography and/or US, we recommend to go on follow-ups with these modalities instead of MRI. The detection frequency, the malignancy rate, negative predictive value, the compliance with our follow-up protocol considering 95% CI were analyzed. The detection frequency on MRI for BI-RADS category 3 lesions was 20.5%. The distribution of MRI findings was as follows: 77.3% mass, 11.4% nonmasslike contrast enhancement, 4.5% focus, 6.9% lymph node. In total, seven lesions underwent core or excisional biopsy, which we recommend biopsy four of them because of interval progression during follow-ups. Biopsy yielded invasive ductal carcinoma in only one lesion (T1N0M0) showing ductal contrast enhancement on MRI. Our NPV was 99,2% (95% CI: from 98,38% to 100,09%). The malignancy rate was calculated as 0.8% (95% CI: from 0.15% to 1.85%). Of 69 patients, 89% of them complied our follow-up protocol by attending at least twice. As a conclusion, malignancy rate with a 0.8% rate is very low in BI-RADS category 3 lesions detected on MRI similar to low malignancy rate provided with mammography and ultrasound. Our criteria meet sufficiently the definition of BI-RADS category 3 on MRI. Key words: Breast, MRI, BI-RADS category 3
Author
Emel Emir Yetim
How to Cite
Emel Emir Yetim (Medical Specialty Thesis). Bi-rads category 3 breast lesions on MRİ; follow-up results, 2018, Akdeniz University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Akdeniz University
- The purpose of present study was to determine the levels of situational anxiety caused by the pressure of the competitive situations exposed to by child athletes and to objectively evaluate the parameters of Heart Rate Variability (HRV) and state anxiety accompanying the change in emotional state.(2022)
- Numerical investigation of the notch effect in interference fit connections(2023)
- Proje tabanlı öğrenimin İngilizce hazırlık sınıfı öğrencilerinin konuşma yeterlilikleri ve iletişim kurma istekleri üzerine etkisi(2025)
- The formation of Medieval Islamic economic thought within the scope of East-West interaction(2024)
- A cost comparison of rubble mound breakwater with breakwater covered by antifer block(2018)
- Enderunlu Fazıl – Hûbân-nâme (Edition critique)(2024)
