Medical SpecialtyOpen Access

Evaluation of natriuretic peptide levels and echocardiography findings in patients with micro AF

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

2023
0 views
0 downloads

Abstract (EN)

Micro-AF, defined as brief episodes of rapid irregular atrial activity, is a predictor for atrial fibrillation (AF), which is an important cause of mortality and morbidity. However, micro-AF may be overlooked diagnosis. The aim of our study is to investigate the predictability of laboratory, electrocardiographic and echocardiographic findings for the diagnosis of micro-AF. Micro-AF was defined as sudden onset of irregular tachycardia with episodes of ≥5 consecutive supraventricular beats and total absence of p-waves, lasting less than 30 s. Two groups were formed as patients with and without Micro-AF detected in 24-hour rhythm Holter analysis. Laboratory parameters, electrocardiographic and echocardiographic findings of the two groups were compared. A total of 90 patients, 45 patients with micro AF and 45 patients in the control group, were included in our study. Serum Troponin T (13,09±11,45 ng/dl and 4,41±2,46 ng/dl; p<0.001) and pro-BNP (375,57±636,68 pg/ml and 63,19±56,82 pg/ml; p<0.001) Micro It was found to be higher in the AF group. Serum ANP values (160,19±83,94 ng/L and 278.63±196.51 ng/L; p<0.001) were higher in the control group.We found a 63.4 pg/dl Pro-BNP cut-off value for the diagnosis of micro-AF with a sensitivity of 91.1% and a specificity of 73.3%. Each 1 pg/dl increase in serum Pro-BNP level increased the risk of Micro-AF by 1.8%. In ECG evaluation, P-max (113,00±10,25 and 98,00±10,47 ms; p<0,001), P-min (73,89±5,53 and 70,00±6,39 ms; p<0,001 ) and P-dd (39,11±7,93 and 28,00±7,64 ms; p<0,001) were longer in the Micro-AF group. In echocardiographic findings, interventricular septum wall thicness (11,14±1,37 and 9,65±2,65 mm; p=0,003), posterior wall thicness (12,13±6,58 and 9,78±2,63 mm;p=0,002) and left atrial diameter ( 35,92±1,30 and 34,62±1,77mm; p<0,001) were found to be higher in the Micro-AF group. In the micro-AF group, mitral A wave velocity was higher (0,79±0,18 and 0,71±0,13 cm/h; p=0,019). e' and s' wave velocities measured were lower, and E/e' ratios were higher from 6 regions. Atrial electro-mechanical delay times (PA) were significantly higher in the Micro AF group. Lateral tricuspid PA cut-off value of 18,5 seconds was determined for micro-AF with a sensitivity of 93,3% and a specificity of 91,1%; Lateral Septal PA cut-off value of 11,5 seconds was determined with 95,6% sensitivity and 75,6% specificity. In conclusion, in our patients who applied to the outpatient clinic with the complaint of palpitation, serum pro-BNP, serum troponin T levels, P-max, P-dd times in ECG evaluation, left atrial diameter in echocardiographic evaluation, E wave velocity, A wave velocity, e' measurement, E/e ' rate and measurement of AEMD durations may allow us to identify AF patients early.

Author

Hüseyin Aykaç

How to Cite

Hüseyin Aykaç (Medical Specialty Thesis). Evaluation of natriuretic peptide levels and echocardiography findings in patients with micro AF, 2023, Tekirdağ Namık Kemal University.

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Tekirdağ Namık Kemal University