Effects of warm sweep gas oxygenation on oxygenator performance
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Several ways have been tried to enhance the activity of oxygenator equipment and to achieve the highest performance in the production of equipment that simulates KPB's lungs. The aim of our work is to evaluate whether it is effective to heat the sweeping gas to increase the oxygenator performance from KPB equipment. When the gases are heated, their motility increases and therefore the pressures increase. When we heat the sweeping gas, the movements of oxygen and pressures will increase, it will pass through the membrane material to the blood side faster and the erythrocyte will be easier to diffuse. Our work was done on a simulation (simulation) model. Some changes were made in the conventional CPB circuit established on the heart-lung machine and the system circuit was prepared. Firstly, as in conventional CPB, the sweeping gas oxygenator was applied to the room heat. Then, sweeping gas was applied at 28⁰C. In both cases, pre-oxygenator and post-oxygenator sato2, PaO2, PaCO2 were followed to observe whether there was any change in oxygenator performance. In addition, total artery emboli number, total artery embolization volume was measured and it was observed whether there was an increase in the rate of gazeous microembolies. This process was repeated at blood temperatures of 16,22,28,32 and 37 ⁰C. When the oxygen-air mixture in the sweeping gas is higher than the blood temperature, the pressurized oxygen membrane material is more easily passed through and the erythrocyte is loaded more efficiently. The fact that work may shift to this direction and we believe that effective oxygenation can be achieved with a minimum oxygen surface area and a lower flow rate. This practice in the simulated model may not be suitable for clinical use, but it provides important concrete information on the ways in which sweeping gas studies may be effective in the performance of the oxygenator. We believe that more and more extensive work on sweeping gas should be done to increase the oxygenation capacity.
Author
Leyla Kaya
Institution
How to Cite
Leyla Kaya (Master Thesis). Effects of warm sweep gas oxygenation on oxygenator performance, 2018, Çanakkale Onsekiz Mart University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Çanakkale Onsekiz Mart University
- Investigation the effects of eight weeks pilates and step-aerobics on sturctural, biomotorical and physiocological variables of sedantery women(2014)
- The Bulgarian Exarchate(1998)
- Determination of the amount of Chernobyl-derived Cs-137 transported through Dardanelles Strait(2012)
- Synthesis and characterization of imine polymers containing carbazole unit(2012)
- Numeri̇c analysi̇s of elasti̇c wave equati̇ons at si̇li̇ndi̇ri̇c coordi̇nates usi̇ng fi̇ni̇te di̇fference method(2014)
- Quantitative determination of paracetamol in drug forms at poly (P-aminobenzenesulfonic acid)-modified glassy carbon electrode(2014)