Determination of spray deposition and drift of turbofan and air-assisted spinning disc nozzles (micromax III, Tarp-2383) in different operating conditions
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
ABSTRACTPh. D. THESISDETERMINATION OF SPRAY DEPOSITION AND DRIFT OF TURBOFAN AND AIR-ASSISTED SPINNING DISC NOZZLES (Micromax III, Tarp-2383) IN DIFFERENTOPERATING CONDITIONSNigar<$538=%2='2ö$1DEPARTMENT OF AGRICULTURAL MACHINERYINSTITUTE OF NATURAL AND APPLIED SCIENCESUNIVERSITY OF CUKUROVASupervisor : Prof. Dr. Ali BAYATYear: 2005, Pages: 134Jury : Prof. Dr. Ali BAYATProf. Dr. Yusuf ZERENProf. Dr. Faruk ÖZGÜVENProf. Dr. Emin GÜZEL3URI'U05ÃIDWULUSOYAlthough spinning disc nozzle produces small and homogenous droplets; itsdrift potential is very high in windy conditions. To reduce these disadvantages, air-assisted system was adapted to a spinning disc nozzle and prototype air assistedspinning disc nozzle was produced. The trials were carried out in laboratoryconditions at different wind velocity (1.5, 2.5 and 3.5 ms-1), air assisted (10, 15 and25 ms-1), application rate (20 and 40 lha-1) and droplet diameters (85 and 210 µm).Moreover, Turbofan nozzle, which is an example model, was examined in laboratoryand field trials. Laboratory studies were carried out in wind tunnel. To determineefficiency of methods used in this experiment, BSF solution was sprayed instead ofpesticide and artificial plants were used as plant. The amounts of BSF on foliar anddrift were determined by fluorometric method. For both nozzles, spray patterndisplacements were determined by using a spray patternator in wind tunnel.In laboratory condition, air-assisted spinning disc nozzle increased spraydeposition in windy condition. Furthermore, the highest spray deposition wasobtained at droplet diameter of 85 µm and application rate of 20 lha-1. Whenspinning disc nozzle was operated at 25 ms-1 air-assisted, drift was partiallycontrolled in 3.5 ms-1 wind velocity. The lowest spray pattern displacement of air-assisted spinning disc nozzle and Turbofan nozzle was obtained at 25 ms-1 air-assisted. Air-assisted could not provide enough penetration in working with spinningdisc nozzle and Turbofan nozzle.Keywords: Air-assisted spinning disc nozzle, Turbofan nozzle, Spray deposits,Spray drift, Spray pattern displacementII
Author
Nigar Yarpuz Bozdoğan
Institution
How to Cite
Nigar Yarpuz Bozdoğan (Doctorate thesis). Determination of spray deposition and drift of turbofan and air-assisted spinning disc nozzles (micromax III, Tarp-2383) in different operating conditions, 2005, Çukurova University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Çukurova University
- An investigation of violent and nonviolent adolescent' families in terms in terms of family fuctioning, anger and anger expression(2006)
- Adolescents who have single parents family and full family were compared in respect to their life satisfaction and quality of life(2009)
- The effects of collaborative video-blog projects on Turkish EFL students' linguistic and digital literacy skills(2025)
- Cultural significance in foreign learning and teaching with special emphasis on reading comprehension through cultural schemata(1992)
- Credit risk management in banking sector: An application of variables determining credit risk in Turkish banking sector(2011)
- Investigation of psychological symptom levels in adolescents according to gender and family functions(2013)
