Structural cost comparission of steel stadium roof
2015
0 görüntülenme
0 i̇ndirme
Danışman: Prof. Dr. Celalettin Kozanoğlu
Özet (EN)
In this study, that is put forward that designing a steel stadium tribune roof with truss and solid webbed system and comparing related cost. The statical calculation of aforementioned building has been accomplished with design loads taken from Design Loads for Buildings (TS498) and Equivalent seismic load method and mode superposition method taken from Turkish Earthquake Code 2007 (DBYBHY-2007) and the results obtained have been compared. Sap 2000 program has been used in the analyses. As a result of comparison, it is established that choosing load-bearing system in steel constructions affects the cost of structure significantly.
Yazar
Recep Suk
Kurum
Bu Yayına Nasıl Atıf Yapılır
Recep Suk (Master Thesis). Structural cost comparission of steel stadium roof, 2015, Manisa Celal Bayar University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Manisa Celal Bayar University tezlerinden daha fazlası
- Investigation of the relationship of internet addiction level of high school students with parents' attitudes: The case of Manisa(2019)
- Analysing the social integration process of yezidi refugee youngs in the context of multiculturalist social work(2016)
- The security matter of Turkey?s Islands? sea (Eagean sea)(2007)
- Middle income trap problem in terms of sustainable growth resources in Turkiye(2023)
- Examining the leadership styles of fitness center managers according to their organizational response to the crisis: The Covid-19 outbreak case(2023)