Evaluation of Transdiaphragmatic Passage of İntraperitoneal İnjected Labelled E.Coli Through Fibrin Sealant (Vivostat®) Coated Diaphragm
2010
0 views
0 downloads
Advisor: Prof. Dr. Sedat Karademir
Abstract (EN)
Transdiaphragmatic passage of bacteria and bacterial products is very important insystemic effects of intraperitoneal infections. In many studies it is shown that blockage oflymphatic stomata may decrease mortality but none of these methods could be clinicallyapplicated. Vivostat® is a bioadaptive, highly adhezive and elastic fibrin sealant that can beeasily and safely applicated to surgical surfaces with its rapid polimerization. There is nocertain information about the blocking effects of fibrin sealant on diaphragma. In this studywe aimed to show the coating effects of vivostat on diaphragmatic lymphatic stomatas andbacterial migration through stomata.Sixteen (2 rats for preperation) adult Wistar- albino rats of 280-300 grams were dividedin 2 groups. Tc 99m pertecnetat labeled E coli is applied to infradiaphragmatic area withlaparotomy in Group 1 (n=7). In group 2 (n=7) the same process was performed after thediaphragma was coated by Vivostat®. Sintigrafic dinamic images were captured at the 20thminute after the abdomen was closed and static images were captured at 1st, 2nd and 6thhours. Rats were sacrified after the 6th hour static screening. Intracardiac blood samples weretaken for blood cultures and radioactivity counts and hepatectomy and spleenectomy wereperformed for tissue radioactivity counts.Early diaphragmatic passage to mediastinal lymphatic system and systemic bloodcirculation were observed in dinamic sintigraphic images for both groups. All the bloodcultures were positive. In group 1 and 2 radioactivity count result were respectively3,4x105±1,2x105, 3,9x105±1,5x105 cpm/ml/min (p=0,655), 5,7x104±2,5x104 7,7x104±2,4x104cpm/gr/min (p=0,277), 3,2x104±1,6x104, 3,5x104±1,8x104 cpm/gr/min (p=0,749) in blood,4liver and spleen samples and there was no statisticaly significant difference between twogroups.This study shows that fibrin sealant (Vivostat®) does not block transdiaphragmaticpassage of labeled E Coli.Key Words: Intraperitoneal, labeled E Coli, vivostat, transdiphraghmatic passage
Author
Dr. Özgür Çavdaroğlu
How to Cite
Özgür Çavdaroğlu (Medical Specialty Thesis). Evaluation of Transdiaphragmatic Passage of İntraperitoneal İnjected Labelled E.Coli Through Fibrin Sealant (Vivostat®) Coated Diaphragm, 2010, Dokuz Eylül University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Dokuz Eylül University
- Analysis of speech clarity parameters in open plans offices(2021)
- AFAD gönüllülük sisteminin etkin müdahale açısından analiz(2020)
- The musical analysis of W. A. Mozart, J. N. Hummel and C. M. Von Weber' s bassoon concertos(2006)
- Examination of martian habitats from the viewpoint ofstructure(2022)
- Environmental graphic design and public installation in the context of 21st century postmodernism(2022)
- Politik pazarlama ve ABD Cumhurbaşkanlığı kampanya stratejileri: Donald Trump ve Hillary Clinton'ın Twitter söylemlerinin fonksiyonel ve retorik analizi(2020)
